5. PARAMETERS
No.
Symbol
PD14
*DOP3
Function selection D-3
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
Name and function
Explanation
For manufacturer setting
Selection of output device at warning occurrence
Select the WNG (Warning) and ALM (Malfunction) output status at
warning occurrence.
Servo amplifier output
Setting
(Note 1) Device status
value
WNG
0
ALM
1
WNG
0
1
1
ALM
0
Note 1. 0: Off
1: On
2. Although ALM is turned off upon occurrence of the
warning, the forced stop deceleration is performed.
For manufacturer setting
1
0
1
0
Warning occurrence
Warning occurrence (Note 2)
5 - 37
Initial
Setting
value
range
[unit]
Refer to the
"Name and
Initial
function" column.
value
0h
0h
0h
0h