Mitsubishi MR-JE-10B Instruction Manual page 275

Mr-je series
Table of Contents

Advertisement

APPENDIX
App. 4.3 Electrical Installation and configuration diagram
WARNING
CAUTION
The following shows representative configuration examples to conform to the IEC/EN/UL/CSA standards.
(1) 3-phase input
(2) 1-phase input
The connectors described by rectangles are safely separated from the main circuits described by circles.
Use MR-JE servo amplifiers in combination with HG series or HJ series servo motors.
Turn off the molded-case circuit breaker (MCCB) to avoid electrical shocks or
damages to the product before starting the installation or wiring.
Connecting a servo motor for different axis to U, V, W, or CN2 of the servo
amplifier may cause a malfunction.
Securely connect the cables in the specified method and tighten them with the
specified torque. Otherwise, the servo motor may operate unexpectedly.
(3-phase
230 V AC)
Power
supply
(3-phase
400 V AC)
Transformer
(star-connected)
To protective equipment
(Thermal signal) (Note)
Note. Please use a thermal sensor, etc. for thermal protection of the servo motor.
(1-phase
230 V AC)
Power
supply
(3-phase
400 V AC)
Transformer
(star-connected)
To protective equipment
(Thermal signal) (Note 1)
Note 1. Please use a thermal sensor, etc. for thermal protection of the servo motor.
2. For the MR-JE-200_ servo amplifiers, connect the power supply to L1 and L2.
Leave L3 open.
MCCB
MC
L1
L2 L3
or fuse
PE
U/V/W/PE
Servo motor
MCCB
MC
L1
L2 L3
or fuse
(Note 2)
PE
U/V/W/PE
Servo motor
App. - 10
Servo amplifier
CN1
Controller
CN2
Encoder cable
Cabinet side
Machine side
Encoder
Servo amplifier
CN1
Controller
CN2
Encoder cable
Cabinet side
Machine side
Encoder