D-Link DXS-1210-12TC Reference Manual page 21

Dxs-1210 series l2 10 gigabit ethernet switch
Hide thumbs Also See for DXS-1210-12TC:
Table of Contents

Advertisement

Command Default Level
Level: 12.
Usage Guideline
This command is used to configure the environment temperature threshold which corresponds to the
normal range of the temperature defined for the sensor. The low threshold must be smaller than the
high threshold. The configured range must fall within the operational range which corresponds to the
minimum and maximum allowed temperatures defined for the sensor. When the configured threshold
is crossed, a notification will be sent.
Example
This example shows how to configure the environment temperature thresholds for thermal sensor ID 1
on unit 1.
Switch# configure terminal
Switch(config)# environment temperature threshold low 20
Switch(config)# environment temperature threshold high 100
2-12
This command is used to configure the environment temperature thresholds. Use the no form of this
command to revert to the default setting.
environment temperature threshold { low | high } <negative>
no environment temperature threshold { low | high } <negative>
Parameters
high
low
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
This command is used to configure the environment temperature threshold which corresponds to the
normal range of the temperature defined for the sensor. The low threshold must be smaller than the
high threshold. The configured range must fall within the operational range which corresponds to the
minimum and maximum allowed temperatures defined for the sensor. When the configured threshold
is crossed, a notification will be sent.
Example
This example shows how to configure the environment temperature thresholds for thermal sensor ID 1
on unit 1.
DXS-1210 Series Smart Managed Switch CLI Reference Guide
environment temperature threshold
(Optional) Specifies the high threshold of the temperature in Celsius.
The range is from -100 to 200.
(Optional) Specifies the low threshold of the temperature in Celsius.
The range is from -100 to 200. The low threshold must be smaller than
the high threshold.