Harmonic MediaGrid Installation And Configuration Manual page 273

Table of Contents

Advertisement

Chapter 8 Hardware Reference
ContentStore 5840 Power Supply Unit LEDs
1
2
Figure 8–53: ContentStore 5840 Power Supply Unit LEDs
Table 8–50: ContentStore 5840 Power Supply Unit LED Descriptions
1. PSU Fail
2. AC Fail
(Amber)
(Amber)
Off
Off
On
On
Off
Off
Off
Off
Flashing
Flashing
Off
On
On
On
On
Disregard
ContentStore 5840 Cooling Module LEDs
Figure 8–54: ContentStore 5840 Cooling Module LEDs
Table 8–51: ContentStore 5840 Cooling Module LED Descriptions
1. Module OK
2. Battery Fault
3. Fan Fault
© 2017 Harmonic Inc. All rights reserved.
3
3. Power
(Green)
Off
No power to either PSU.
Off
PSU present, but not supplying power or PSU alert state (usually
due to critical temperature.
On
Main AC present, switch on. This PSU is providing power.
Flashing
AC power present, PSU in standby (other PSU is providing power.)
Off
PSU firmware download.
Off
AC power missing, PSU in standby (other PSU is providing power).
On
Harmonic MediaGrid software has lost communication with the
PSU.
Off
PSU has failed. For replacement instructions, see the Harmonic
MediaGrid Component Replacement Instructions.
1
2
3
LED
Constant green: indicates that the fan is working correctly.
Off: the fan has failed. For replacement instructions, see the
Harmonic MediaGrid Component Replacement Guide.
Not currently used.
Amber indicates that a fan has failed.
Status
Description
273