Harmonic MediaGrid Installation And Configuration Manual page 258

Table of Contents

Advertisement

Chapter 8 Hardware Reference
Symbol
4
5
6
Disk Drive Status LEDs
Refer to
Figure 8–38
Harmonic MediaGrid Component Replacement Guide for instructions on replacing a failed drive.
LEDs
Figure 8–38: Disk Drive Status LEDs
© 2017 Harmonic Inc. All rights reserved.
LED
Color/State
Heartbeat
Flashing
SAS-In
Solid
Overheat/ Fan Fail
Flashing
Solid
and
Table 8–37
for information on the Disk Drive Status LEDs. Refer to the
Indicates that power is being supplied to the
server board
Indicates that the SAS input port is
connected.
Indicates fan failure
Overheat condition, which may be caused
by cables obstructing the airflow in the
system or the ambient room temperature
being too warm. Check the routing of the
cables and make sure all fans are present
and operating normally. You should also
check to make sure that the chassis covers
are installed. Finally, verify that the heats
inks are installed properly
258
ContentStore 3160
Description
Harmonic MediaGrid Release 4.1

Advertisement

Table of Contents
loading

Table of Contents