Harmonic MediaGrid Installation And Configuration Manual page 256

Table of Contents

Advertisement

Chapter 8 Hardware Reference
1
Drive 15
Figure 8–36: ContentStore 3160 Front Panel
Table 8–35: ContentServer 3160 Front Panel Components
1. Left Control Panel
2. Disk drives
3. Power button and Right Control
Panel
© 2017 Harmonic Inc. All rights reserved.
Component
2
The control panel included on the left side of the
ContentServer 3000 provides system monitoring and
control for the controller on the same side of the chassis.
LEDs indicate system power, network (NIC) activity,
system overheat and power supply failure for the
controller on the left side.
The server contains 16 SATA or SAS disk drives, providing
storage for the Harmonic MediaGrid.Drives are numbered
from right to left when facing the front panel.
There is a single, shared power button located on the
right control panel. Note the following behaviors when
powering on/off with the shared power button:
When both nodes are powered on, depressing this
button will power both nodes off.
When both nodes are powered off, pressing this
button will power both nodes on.
If one node is powered on, pressing this button will
power on a single node with no impact on the node
that is already powered on.
Powering off with this button removes the main power
but keeps standby power supplied to the system.
The control panel included on the right side of the
ContentServer 3000 provides system monitoring and
control for the controller on the same side of the chassis.
LEDs indicate system power, network (NIC) activity,
system overheat and power supply failure for the
controller on the right side.
256
ContentStore 3160
Drive 0
Description
Harmonic MediaGrid Release 4.1
3

Advertisement

Table of Contents
loading