Configuring MP through an MP-group interface

When you configure MP through an MP-group interface, follow these guidelines:
The ppp mp max-bind command and the ppp mp min-fragment command you configured
can take effect on an MP bundle only after you re-enable all the physical interfaces in the MP
bundle by executing the shutdown command and then the undo shutdown command.
After you configure the undo ppp mp fragment enable command on an interface, the settings
configured with the ppp mp lfi and ppp mp min-fragment commands become invalid on the
interface.
To configure MP through an MP-group interface:
Step
Enter system view.
1.
Create an MP-group
2.
interface and enter its view.
Set the maximum number of
3.
links in an MP bundle.
Configure the MP sort buffer
4.
size factor.
Enable MP fragmentation.
5.
Set the minimum size of MP
6.
fragments.
Set the interface description.
7.
Set the MTU size of the
8.
interface.
Set the intended bandwidth
9.
for the MP-group interface.
10. Restore the default settings
for the MP-group interface.
11. Bring up the interface.
12. Return to system view.
13. Enter interface view.
14. Configure software support
for MP binding.
15. Add the interface to the
MP-group and configure it to
operate in MP mode.
Command
system-view
interface mp-group mp-number
ppp mp max-bind max-bind-num
ppp mp sort-buffer-size size
ppp mp fragment enable
ppp mp min-fragment size
description text
mtu size
bandwidth bandwidth-value
default
undo shutdown
quit
interface interface-type
interface-number
ppp mp soft-binding
ppp mp mp-group mp-number
22
Remarks
N/A
N/A
Optional.
The default setting is 16.
Optional.
The default setting is 1.
Optional.
By default, MP fragmentation is
disabled.
Optional.
The default setting is 128 bytes.
Optional.
By default, the description of an
MP-group interface is interface
name Interface.
1500 bytes by default.
Optional.
Optional.
Optional.
By default, the interface is up.
N/A
N/A
By default, MP binding is
supported in hardware.
Software support for MP binding
can only be configured on CPOS
interfaces.
N/A