Viewing The Sample Rate Converted Status For The Selected Path; Setting The Cc1 To Cc4 Service Controls; Setting The T1 To T4 Service Controls - evertz HD2014 User Manual

Video passport 1ru multi-path video converter, frame synchronizer and decoder
Table of Contents

Advertisement

5.1.2.2.

Viewing the Sample Rate Converted Status for the Selected Path

For each processing path, the status of converter's internal sample rate converters is reported as part
of the overall audio monitoring process. Select SRC STATUS menu selection to determine status of the
converters embedded audio sample rates converters.
VIDEO
Processing
Converter
VIDEO
Audio Monitor
Src Status
Enable or Disable
5.1.2.3.

Setting the CC1 to CC4 Service Controls

Each processing path in the HD201x performs full closed caption processing. When converting from
CEA608 to CEA708 captions, specific controls are made available for mapping cc1, cc2, cc3 and cc4
services. For the sake of brevity, only controls for CC1 will be mentioned below. Controls for cc2, cc3
and cc4 are identical. Select CC1 TO EIA708SERVICE to control cc1 mapping.
VIDEO
Processing
Converter
Path 1
Caption
cc1ToEIA708Service
Off,
1
to
16
5.1.2.4.

Setting the T1 to T4 Service Controls

Each processing path performs full closed caption processing. When converting from CEA608 to
CEA708 captions, specific controls are made available for mapping T1, T2, T3 and T4 services. For the
sake of brevity, only controls for T1 will be mentioned below. Controls for T2, T3 and T4 are identical.
Select T1 TO EIA708SERVICE to control T1 mapping.
VIDEO
Processing
Converter
Path 1
Caption
t1ToEIA708Service
Off,
1
to
16
FRONT PANEL OPERATION
HD2014, HD2012, HD2011 Video Passport
1RU Multi-Path Video Converter, Frame Synchronizer and Decoder
Audio sample rate converter status is reported when this parameter is
selected. Sample rates converters are disabled when any non PCM
audio data (ie. Dolby E) is present in the embedded audio stream.
The CC1 Service Control will be mapped to the CEA708 Service N,
where N is the selected parameter values. When CC1 Service
Control is set to off, the CC1 is not mapped to any EIA708 Caption
Service.
The T1 Service Control will be mapped to the CEA708 Service N,
where N is the selected parameter values. When T1 Service Control is
set to off, the T1 is not mapped to any EIA708 Caption Service.
Revision 0.1
TM
Page 5-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd2012Hd2011

Table of Contents