3.8.
PHYSICAL
Dimensions:
With mounting flanges:
Weight:
4.
STATUS LED'S
The locations of the status indicators are shown in Figure 2-1.
POWER:
Indicates that the 2430GDAC-WARP is receiving electrical power.
FAULT:
When on, indicates that the input G-Link signal (either coaxial or fiber) is not being
received.
5.
USER CONTROLS
The 2430GDAC-WARP has a 4 position DIP switch that is used to configure several features. The On
position is down or closest to side of the unit with the flanges. Table 5-1 gives an overview of the DIP
switch functions.
5.1.1. Input Source Selection
DIP switch 1 selects the input G-Link source.
5.1.2. Video Resolution
DIP switch 2 selects the output resolution mode.
7.2" L x 4.3" W x 1.0" H
(166mm L x 110mm W x 26mm H)
7.2" L x 5.3" W x 1.0" H
(166mm L x 136mm W x 26mm H)
0.85 lbs. (0.38 kg)
DIP Switch
Function
1
Fiber/coaxial input select
2
Auto/manual resolution select
3
Resolution select
4
Table 5-1: DIP Switch functions
DIP 1
Off
Fiber Input
On
Coaxial Input
Table 5-2: Input Source Switch Settings
DIP 2
Off
Manual Resolution Select
On
Automatic Resolution Detect
Table 5-3: Input Source Switch Settings
Revision 1.2
2430GDAC G-Link D to A Converter
Video Source
Video Source
2430GDAC-7