Lenovo System x3300 M4 Installation And Service Manual page 94

Machine type: 7382
Hide thumbs Also See for System x3300 M4:
Table of Contents

Advertisement

Hazardous voltage, current, and energy levels are present inside any component that has this label
attached. There are no serviceable parts inside these components. If you suspect a with one of these
parts, contact a service technician.
To install a hot-swap power supply, complete the following steps:
Note: You must install the fan assembly before removing or installing the power supply.
Step 1.
Read the safety information that begins in "Safety" on page v and "Installation guidelines" on
page 34.
Attention: Static electricity that is released to internal server components when the server is
powered-on might cause the server to halt, which might result in the loss of data. To avoid this
potential problem, always use an electrostatic-discharge wrist strap or other grounding system
when you work inside the server with the power on.
Step 2.
Touch the static-protective package that contains the hot-swap power supply to any unpainted
metal surface on the server; then, remove the power supply from the package and place it on
a static-protective surface.
Step 3.
Remove the power-supply filler panel from the power bay, if one is installed.
Step 4.
Install the power supply and push it in until it locks into place.
Notes:
• If only one hot-swap power supply is installed in the server, a power-supply filler must be
installed in the empty power bay.
80
System x3300 M4 Installation and Service Guide

Advertisement

Table of Contents
loading