Hazardous voltage, current, and energy levels are present inside any component that has this label
attached. There are no serviceable parts inside these components. If you suspect a with one of these
parts, contact a service technician.
To install a hot-swap power supply, complete the following steps:
Note: You must install the fan assembly before removing or installing the power supply.
Step 1.
Read the safety information that begins in "Safety" on page v and "Installation guidelines" on
page 34.
Attention: Static electricity that is released to internal server components when the server is
powered-on might cause the server to halt, which might result in the loss of data. To avoid this
potential problem, always use an electrostatic-discharge wrist strap or other grounding system
when you work inside the server with the power on.
Step 2.
Touch the static-protective package that contains the hot-swap power supply to any unpainted
metal surface on the server; then, remove the power supply from the package and place it on
a static-protective surface.
Step 3.
Remove the power-supply filler panel from the power bay, if one is installed.
Step 4.
Install the power supply and push it in until it locks into place.
Notes:
• If only one hot-swap power supply is installed in the server, a power-supply filler must be
installed in the empty power bay.
80
System x3300 M4 Installation and Service Guide