Lenovo System x3300 M4 Installation And Service Manual page 156

Machine type: 7382
Hide thumbs Also See for System x3300 M4:
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 5 "Parts listing, Lenovo System x3300 M4 Type 7382" on page 153 to check if a component is a
structural, or FRU part.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Symptom
The Pwr rail 4 error has been
recorded in the IMM2 event
log.
The Pwr rail 5 error has been
recorded in the IMM2 event
log.
142
System x3300 M4 Installation and Service Guide
Action
1. Disconnect the server power cords.
2. Remove the following components if the Pwr rail 4 error has been recorded
in the IMM2 event log:
• Fan 4
• DIMMs 1 through 12
• (Trained technician only) microprocessor 2 (see "Removing a microprocessor
and heat sink" on page 266.)
3. Restart the server. If the Pwr rail 4 error has been recorded in the IMM2
event log again, (trained technician only) replace the Power Paddle Card (see
"Installing the power paddle card" on page 77.)
4. Reinstall the components one at a time, in the order shown, restarting the
server each time. If the Pwr Rail 4 error has been recorded in the IMM2 event
log again, the component that you just reinstalled is defective. Replace the
defective component.
• (Trained technician only) replace microprocessor 2 (see "Installing a
microprocessor and heat sink" on page 71.)
• DIMMs 1 through 12
• Fan 4
5. (Trained technician only) replace System board (see "Replacing the system
board" on page 279.)
1. Disconnect the server power cords.
2. Remove the following components if the Pwr rail 5 error has been recorded in
the IMM2 event log for the hot-swap power-supply systems:
• Hard disk drives
• Hard disk drive backplane assembly
• Optional DVD or Tape drive (if one is present)
3. Restart the server. If the Pwr rail 5 error has been recorded in the IMM2
event log again, (trained technician only) replace the Power Paddle Card (see
"Installing the power paddle card" on page 77.)
4. Reinstall the components one at a time, in the order shown, restarting the
server each time. If the Pwr Rail 51 error has been recorded in the IMM2 event
log again, the component that you just reinstalled is defective. Replace the
defective component for the hot-swap power-supply systems:
• Optional DVD or Tape drive (if one was present)
• Hard disk drive backplane assembly
• Hard disk drives
5. (Trained technician only) replace System board (see "Replacing the system
board" on page 279.)

Advertisement

Table of Contents
loading

Table of Contents