Latest level of BMC/IMM
166-818-001 : IMM I2C Test Aborted
Cannot execute duplicated request.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
166-819-001 : IMM I2C Test Aborted
Command response could not be provided. SDR Repository in?update mode.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.