Lenovo System x3300 M4 Installation And Service Manual page 164

Machine type: 7382
Hide thumbs Also See for System x3300 M4:
Table of Contents

Advertisement

Step 4.
Move the jumper from pins 1 and 2 to pins 2 and 3 to enable the UEFI recovery mode.
Step 5.
Reinstall the server cover; then, reconnect all power cords.
Step 6.
Restart the server. The power-on self-test (POST) starts.
Step 7.
Boot the server to an operating system that is supported by the Lenovo Flash UEFI Update
package that you downloaded.
Step 8.
Perform the firmware update by following the instructions that are in the firmware update package
readme file.
Step 9.
Copy the downloaded firmware update package into a directory.
Step 10. From a command line, type filename-s, where filename is the name of the executable file that you
downloaded with the firmware update package.
Step 11. Turn off the server and disconnect all power cords and external cables, and then remove the
server cover.
Step 12. Move the UEFI boot recovery jumper back to the primary position (pins 1 and 2).
Step 13. Reinstall the server cover, and then reconnect all the power cables.
Step 14. Restart the server.
In-band automated boot recovery method
1. Boot the server to an operating system that is supported by the firmware update package that you
downloaded.
2. Perform the firmware update by following the instructions that are in the firmware update package
readme file.
3. Restart the server.
150
System x3300 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents