Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the
power-supply fan.
2. Use the IBM Power Configurator utility to ensure current system power consumption
is under limitation. For more information and to download the utility, go to
http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
3. Replace power supply n. (n = power supply number)
• 8007020f-2201ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (TXT ACM Module)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020f2201ffff or 0x8007020f2201ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
1. If enabling TXT is not required, disable TXT from the Setup Utility.
2. If enabling TXT is required, verify that the TPM is enabled and activated from the Setup Utility.
3. If the problem remains, contact your service representative.
• 8007020f-2582ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (I/O Resources)