3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
816f000d-040effff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 14)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d040effff or 0x816f000d040effff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
816f000d-040fffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 15)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d040fffff or 0x816f000d040fffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
580