Lenovo System x3300 M4 Installation And Service Manual page 20

Machine type: 7382
Hide thumbs Also See for System x3300 M4:
Table of Contents

Advertisement

Table 1. Server features and specifications (continued)
board that supports two DIMMs
per channel
Notes:
• Use the Setup utility program to
determine the type and speed of
the microprocessors
• For a list of supported
microprocessors, see
http://www.lenovo.com/
serverproven/.
Fans:
• The server comes standard with
two speed-controlled fans for
one-microprocessor configuration
• Support up to four fans with
two microprocessors installed
(including one redundant fan)
RAID controllers:
• ServeRAID C105 supports up to
eight SATA ports
– support for RAID level 0, 1 and
10
– support 3.5-inch SATA 3TB
HDDs
– support HDD simple-swap and
hot-swap
– support 4 SATA HDDs in default
(can be upgraded to 8 SATA
HDDs via FoD key)
Notes:
• In 2.5" system, two internal
SAS cable connecting SAS
RAID controller to SAS hard
drive backplane. One type of
backplanes will be used to support
eight 2.5" hot-swap HDDs. In
addition, the system will use 2
types of backplanes to support
sixteen 2.5" hot-swap HDDs
• In 3.5" system, two internal SAS
cable is required to support eight
3.5" hot-swap HDDs with the
required backplane
PCI and PCI-X expansion slots:
• Six PCI-e expansion slots on the
system board
6
System x3300 M4 Installation and Service Guide
– Single-rank, Dual-rank or
Quad-rank DDR3
– UDIMM/RDIMM, up to 32 GB
• Support:
– UDIMM: 2 GB, 4 GB, or 8 GB
– RDIMM: 2 GB, 4 GB, 8 GB, 16
GB
Environment:
The Lenovo System X3300 compute
node complies with ASHRAE class
A3 specifications.
• Power on:
– Temperature: 5°C - 40°C
(41°F - 104°F) up to 950mm
(3,117ft) Above 950m, de-rated
maximum air temperature 1C /
175m
– Humidity, non-condensing:
-12°C dew point (10.4°F) and
8% - 85% relative humidity
– Maximum dew point: 24°C
(75°F)
– Maximum altitude: 3050 m
(10,000 ft) & 5°C - 28°C (41°F -
82°F)
– Maximum rate of temperature
change: 5°C/hr (41°F/hr) for
tape drive, 20°C/hr (68°F/hr) for
HDDs
• Power off:
– Temperature: 5°C to 45°C (41°F
- 113°F)
– Relative humidity: 8% - 85%
– Maximum dew point: 27°C
(80.6°F)
• Storage (non-operating)
– Temperature: 1°C to 60°C
(33.8°F - 140°F)
– Altitude: 3050 m (10,000 ft)
– Relative humidity: 5% - 80%
Attention: As a general consideration,
do not mix standard 512-byte and
advanced 4-KB format drives in the
same RAID array because it might
lead to potential performance issues.
Notes:
• LSI C105 ServeRAID only support
SATA HDD models
• LSI C105 does not support
VMware
• The system board does not
support parallel IDE/ATA interface.
No floppy disk Interface connector
and no embedded floppy disk
drive is supported
Optional SATA optical drives:
• Two Patsburg SATA ports for:
– DVD-ROM
– Multi-Burner (Rambo)
Heat output:
Approximate heat output in British
thermal units (Bts):
• Minimum configuration: 392 Btu
per hour (ac 115 watts)
• Maximum configuration: 2900 Btu
per hour (ac 850 watts)
Integrated functions:
• Integrated Management Module
II (IMM2), which provides service
processor control and monitoring
functions, video controller, and
remote keyboard, video, mouse,
and remote hard disk drive
capabilities
• Onboard Intel Powerville Gigabit
Ethernet controller with Wake
on LAN support. The controller
provides up to four ports when the
optional Feature on Demand (FoD)
feature is activated.
• Combine "Intel PCH SAS/SATA
RAID controller which supports for
RAID levels 0, 1 and 10 with SW
RAID controller - ServeRAID C105
• Light path diagnostics
• Eight Universal Serial Bus (USB)
2.0 ports:
– Two on the front of the chassis
– Four on the rear of the chassis
– Two internal USB ports: one is
for option USB flash device with

Advertisement

Table of Contents
loading

Table of Contents