Lenovo System x3300 M4 Installation And Service Manual page 509

Machine type: 7382
Hide thumbs Also See for System x3300 M4:
Table of Contents

Advertisement

Prefix: PLAT ID: 0104
User Response
1. Make sure that the power supplies installed are with the same rating or wattage.
2. Reinstall the power supplies with the same rating or wattage.
• 806f060d-0400ffff : Array [ComputerSystemElementName] has failed. (Drive 0)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0400ffff or 0x806f060d0400ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
• 806f060d-0401ffff : Array [ComputerSystemElementName] has failed. (Drive 1)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0401ffff or 0x806f060d0401ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Appendix A. Integrated management module II (IMM2) error messages
495

Advertisement

Table of Contents
loading

Table of Contents