Cd/Dvd Drive Problems; Hypervisor Problems - Lenovo System x3300 M4 Installation And Service Manual

Machine type: 7382
Hide thumbs Also See for System x3300 M4:
Table of Contents

Advertisement

3. Run Dynamic System Analysis (DSA) to determine whether the server is running correctly (for information
about using DSA, see Appendix C "DSA diagnostic test results" on page 715.
4. Reinstall the new software or new device.

CD/DVD drive problems

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 5 "Parts listing, Lenovo System x3300 M4 Type 7382" on page 153 to check if a component is a
structural, or FRU part.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Symptom
The CD-ROM/DVD-ROM drive
is not recognized.
A CD or DVD is not working
correctly.
The CD or DVD drive tray is not
working.

Hypervisor problems

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 5 "Parts listing, Lenovo System x3300 M4 Type 7382" on page 153 to check if a component is a
structural, or FRU part.
130
System x3300 M4 Installation and Service Guide
Action
1. Make sure that:
• The SATA connector to which the CD or DVD drive is attached (primary or
secondary) is enabled in the Setup utility.
• All cables and jumpers are installed correctly.
• The correct device driver is installed for the CD or DVD drive.
2. Run the CD or DVD drive diagnostic programs.
3. Reseat the following components:
a. CD or DVD drive
b. CD or DVD drive cable
4. Replace the components listed in step 3 one at a time, in the order shown,
restarting the server each time.
5. (Trained service technician only) Replace the system board.
1. Clean the CD or DVD.
2. Replace the CD or DVD with new CD or DVD media.
3. Run the CD or DVD drive diagnostic programs (see Appendix C "DSA diagnostic
test results" on page 715).
4. Reset the CD or DVD drive (see "Removing an optical CD/DVD drive" on page
203 and "Installing an optical CD/DVD drive" on page 55).
5. Replace the CD or DVD drive.
1. Make sure that the server is turned on.
2. Insert the end of a straightened paper clip into the manual tray-release opening.
3. Reset the CD or DVD drive (see "Removing an optical CD/DVD drive" on page
203 and "Installing an optical CD/DVD drive" on page 55).
4. Replace the CD or DVD drive.