401-000-000 : EXA Port Ping Test Passed
EXA Port Ping Test Passed.
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
401-801-000 : EXA Port Ping Test Aborted
EXA Port Ping Test Aborted. Unable to get device base address.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Remove power cables, wait for 45 seconds, reconnect and rerun the test.
2. Make sure that the scalability cable connections are as per specification.
3. Make sure that DSA and BIOS/uEFI are at the latest level.
4. If the problem remains, contact your technical-service representative.
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
401-802-000 : EXA Port Ping Test Aborted
EXA Port Ping Test Aborted. Port connections may not be correct.
Recoverable
744
System x3300 M4 Installation and Service Guide

Advertisement