Lenovo System x3300 M4 Installation And Service Manual page 412

Machine type: 7382
Hide thumbs Also See for System x3300 M4:
Table of Contents

Advertisement

User Response
No action; information only.
806f000f-220101ff : The System [ComputerSystemElementName] has detected no memory in
the system. (ABR Status)
This message is for the use case when an implementation has detected that memory was detected in
the system.
May also be shown as 806f000f220101ff or 0x806f000f220101ff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0794
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Recover the server firmware from the backup page: a. Restart the server. b. At the prompt,
press F3 to recover the firmware.
3. Update the server firmware on the primary page. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
4. Remove components one at a time, restarting the server each time, to see if the problem
goes away.
5. If the problem remains, (trained technician only) replace the system board.
Firmware Error : Sys Boot Status :
806f000f-220102ff : Subsystem [MemoryElementName] has insufficient memory for operation.
(ABR Status)
This message is for the use case when an implementation has detected that the usable Memory is
insufficient for operation.
May also be shown as 806f000f220102ff or 0x806f000f220102ff
Severity
Error
398
System x3300 M4 Installation and Service Guide