Printed Circuit Board Connector Wiring Diagram
1.4

Wall Mounted Type 50/60/71 Class

Connectors
PCB(1) (Control PCB)
1)
2)
3)
4)
5)
6)
7)
8)
PCB(2) (Signal Receiver PCB)
1)
PCB(3) (Buzzer PCB)
1)
2)
PCB(4) (Display PCB)
1)
PCB(5) (INTELLIGENT EYE sensor PCB)
1)
Note:
Other designations
PCB(1) (Control PCB)
1)
2)
3)
4)
PCB(2) (Signal Receiver PCB)
1)
PCB(3) (Buzzer PCB)
1)
PCB(4) (Display PCB)
4)
5)
6)
44
S1
Connector for DC fan motor
S6
Connector for swing motor (horizontal blades)
S8
Connector for swing motor (vertical blades)
S21
Connector for
S26
Connector for buzzer PCB
S28
Connector for signal receiver PCB
S32
Connector for heat exchanger thermistor
S35
Connector for Intelligent Eye sensor PCB
S29
Connector for control PCB
S27
Connector for control PCB
S38
Connector for display PCB
S37
Connector for buzzer PCB
S36
Connector for control PCB
V1
Varistor
JA
Address setting jumper
JB
Fan speed setting
JC
Power failure recovery function
Refer to page 163 for detail.
LED A
LED A for service monitor (green)
FU1
Fuse
(3.15A)
SW1 (S1W)
Forced operation ON/OFF switch
RTH1 (R1T)
Room temperature thermistor
LED1
LED for operation (green)
LED2
LED for timer (yellow)
LED3
LED for HOME LEAVE operation (red)
centralized control
(HA)
when compressor is OFF on thermostat
Printed Circuit Board Connector Wiring Diagram