Daikin E-Series Service Manual page 437

Hide thumbs Also See for E-Series:
Table of Contents

Advertisement

Wiring Diagrams
2.3.2 Duct Connected Type
CDKS25/35/50/60CVMA, CDKS25/35EAVMA, FDXS25/35/50/60CVMA, CDXS25/35EAVMA
PCB1
PCB2
LED
LED
LED
S1
S26
1
1
H1P
H2P
H3P
S1W
SIGNAL
10
10
RECEIVER
2 RTH1
S32
1
2
BRN
R1T
R2T
WIRELESS
REMOTE
C1
CONTROLLER
F1U :
424
(
)
TERMINAL FOR
CENTRALIZED CONTROL
S21
S1
RED
S7
1
GRY
1
3
BRN
PPL
indoor
BLU
:
PROTECTIVE EARTH
CAPACITOR ( M1F )
:
FUSE
H1
F1U
V1TR
3.15A
H2
H3
TRANSMISSION
GND
6
3
1
CIRCUIT
BLK
YLW
H1P ~ H3P
C1
M1F
WHT
PCB1 ~ PCB2
Q1M
M
~
1
Q1M
R1T ~ R2T
130°C
S1 ~ S32, RTH1
M1F
S1W
V1TR
X1M
Z1C
X1M
1
BLK
WHT
2
RED
3
Z1C
GRN
/
YLW
N=2
FIELD WIRING.
GRN
/
YLW
CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
: PILOT LAMP
: FAN MOTOR
: PRINTED CIRCUIT BOARD
: THERMAL PROTECTOR ( M1F EMBEDDED )
: THERMISTOR
: CONNECTOR
: OPERATION SWITCH
: PHASE CONTROL CIRCUIT
: TERMINAL BLOCK
: NOISE FILTER ( FERRITE CORE )
SiAU18-715
1
2
3
outdoor
3D045012K
Appendix

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents