SiAU18-715
3. OPERATION RANGE
If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the
air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING ONLY TYPE
TEMPERATURE[°C]
OUTDOOR
–5 to 46(DB)
HEAT PUMP TYPE
OPERATION
COOLING
HEATING
D B: Dry bulb temperature
WB: Wet bulb temperature
The setting temperature range of the remote con-
troller is 16°C to 32°C.
4. INSTALLATION SITE
Regarding places for installation
• Is the air conditioner installed at a well-ventilated
place where there are no obstacles around?
• Do not use the air conditioner in the following
places.
a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring
resort
d. Where there are considerable voltage fluctua-
tions such as a factory or plant
e. Vehicles and vessels
f . Where there is much spray of oil and vapor
such as a cookery, etc.
g. Where there are machines generating electro-
magnetic waves
h. Filled with acid and/or alkaline steam or vapor
• Is a snow protection measure taken?
For details, consult your dealer.
Operation Manual
INDOOR
21 to 32(DB)/
14 to 23(WB)
TEMPERATURE[°C]
OUTDOOR
INDOOR
21 to 32(DB)/
–5 to 46(DB)
14 to 23(WB)
–14 to 21(DB)/
14 to 28(DB)
–15 to 15.5(WB)
Regarding wiring
• All wiring must be performed by an authorized
electrician.
To do wiring, ask your dealer. Never do it by yourself.
• Make sure that a separate power supply cir-
cuit is provided for this air conditioner and
that all electrical work is carried out by quali-
fied personnel according to local laws and
regulations.
Pay attention to running noises, too
• Are the following places selected?
a. A place that can sufficiently withstand the
weight of the air conditioner with less running
noises and vibrations.
b. A place where the hot wind discharged from the
air outlet of the outdoor unit and the running
noises.
• Are you sure that there are no obstacles near
the air outlet of the outdoor unit?
Such obstacles may result in declined perfor-
mance and increased running noises.
• If abnormal noises occur in use, consult your
dealer.
Regarding drainage of drain piping
• Is the drain piping executed to perform com-
plete drainage?
If proper drainage is not carried out from the out-
door drain pipes during air-conditioning operation,
chances are that dust and dirt are clogged in the
pipe. This may result in a water leakage from the
indoor unit. Under such circumstances, stop the
operation of the air conditioner, and then consult
your dealer or our service station.
Instruction
279