Installation site requirements of the outdoor unit..................62 7.1.2 Additional installation site requirements of the outdoor unit in cold climates..........65 7.1.3 Installation site requirements of the indoor unit ..................65 Installer reference guide EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 3
Overview: Configuration..............................128 10.1.1 To access the most used commands ......................129 10.2 Configuration wizard............................... 131 10.3 Possible screens ................................132 10.3.1 Possible screens: Overview ..........................132 EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 4
14.3.10 Symptom: The pressure at the tapping point is temporarily unusually high..........243 14.3.11 Symptom: Tank disinfection function is NOT completed correctly (AH-error)..........243 14.4 Solving problems based on error codes ......................... 244 Installer reference guide EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 5
Wiring diagram: Outdoor unit ............................257 16.5 Wiring diagram: Indoor unit ............................262 16.6 ESP curve: Indoor unit..............................268 17 Glossary 18 Field settings table EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Format: Paper (in the box of the indoor unit) + Digital files on http:// www.daikineurope.com/support-and-manuals/product-information/ Latest revisions of the supplied documentation may be available on the regional Daikin website or via your dealer. The original documentation is written in English. All other languages are translations. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W...
About the documentation Technical engineering data ▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required).
How to unpack the units and remove their accessories About the units and options ▪ How to identify the units ▪ Possible combinations of units and options EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 9
Note: There is also an installer settings table in the user reference guide. This table has to be filled in by the installer and handed over to the user. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Improper installation or attachment of equipment or accessories could result in electrical shock, short-circuit, leaks, fire or other damage to the equipment. ONLY use accessories, optional equipment and spare parts made or approved by Daikin. WARNING Make sure installation, testing and applied materials comply with applicable legislation (on top of the instructions described in the Daikin documentation).
Make sure the field piping and connections are NOT subjected to stress. WARNING During tests, NEVER pressurize the product with a pressure higher than the maximum allowable pressure (as indicated on the nameplate of the unit). EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 12
Only use tools exclusively for the refrigerant type used in the system, this to ensure pressure resistance and prevent foreign materials from entering into the system. ▪ Charge the liquid refrigerant as follows: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
If NOT factory installed, a main switch or other means for disconnection, having a contact separation in all poles providing full disconnection under overvoltage category III condition, MUST be installed in the fixed wiring. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 14
Install power cables at least 1 m away from televisions or radios to prevent interference. Depending on the radio waves, a distance of 1 m may not be sufficient. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 15
Running the product in reversed phase can break the compressor and other parts. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
(example: open flames, an operating gas appliance or an operating electric heater). WARNING Make sure installation, servicing, maintenance and repair comply with instructions from Daikin and with applicable legislation and are executed ONLY by authorised persons. Mounting the outdoor unit (see "7.3 Mounting the outdoor unit" [...
Page 17
WARNING Ethylene glycol is toxic. "9 Electrical installation" [ 96]) Electrical installation (see DANGER: RISK OF ELECTROCUTION EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 18
If the supply cord is damaged, it MUST be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. CAUTION Do NOT push or place redundant cable length in the unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 19
To protect the piping connected to the magnetic filter/dirt separator from damage it is recommended to perform this procedure with the magnetic filter/dirt separator removed from the unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 20
If yes, make sure that the room where you want to purge air is sufficiently ventilated. Reason: Refrigerant might leak into the water circuit, and subsequently into the room when you purge air from the heat emitters or collectors. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
To avoid injury, do NOT touch the air inlet or aluminium fins of the unit. Crane Keep the slings within the marked area to not damage the unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 22
After unpacking, carry the unit using the slings attached to the unit. See also: ▪ "4.2.2 To unpack the outdoor unit" [ 23] ▪ "7.3.4 To install the outdoor unit" [ 72] ±150 4× EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
About the box 4.2.2 To unpack the outdoor unit EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Bring the packed unit as close as possible to its final installation position to prevent damage during transport. ▪ Unpack the indoor unit completely according to the instructions mentioned on the unpacking instructions sheet. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Sealing tape for low voltage wiring intake 4.3.3 To handle the indoor unit Use the handles at the back and at the bottom to carry the unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 26
Handles at the back of the unit b Handles at the bottom of the unit. Carefully tilt the unit to the back so that the handles become visible. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Explanation European hydro-split outdoor pair heat pump High water temperature – ambient zone 2 (see operation range) Refrigerant R32 Capacity class Model series Power supply EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
EKMST2 with rubber feet: to install the outdoor unit on foundations where drilling is not allowed or possible, such as flat roofs or pavements. For installation instructions, see the installation manual of the mounting stand. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
As an option the remote indoor sensor can be installed to measure the room temperature on another location. For installation instructions, see the installation manual of the remote indoor sensor and addendum book for optional equipment. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 30
Bizone kit (EKMIKPOA or EKMIKPHA) You can install an optional bizone kit. For installation instructions, see the installation manual of the bizone kit. See also: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 31
The installation of the optional Smart grid relay kit is required in case of high voltage Smart grid contacts (EKRELSG). For installation instructions, see "9.3.11 To connect a Smart Grid" [ 122]. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Setting up the domestic hot water tank ▪ Setting up the energy metering ▪ Setting up the power consumption control ▪ Setting up an external temperature sensor EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Automatic. NOTICE An overpressure bypass valve can be integrated in the system. Keep in mind that this valve might not be shown on the illustrations. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
For your daily needs, you can use preset values and schedules. To deviate from your daily needs, you can temporarily overrule the preset values and schedules, or use the holiday mode. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 35
Code: [C-05] heating or cooling demand. Benefits ▪ Wireless. The Daikin external room thermostat is available in a wireless version. ▪ Efficiency. Although the external room thermostat only sends ON/OFF signals, it is specifically designed for the heat pump system. ▪...
Page 36
OFF condition. No separation between ▪ Code: [C-05] heating or cooling demand. Benefits ▪ Cooling. The heat pump convector offers, besides heating capacity, also excellent cooling capacity. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 37
▪ The space operation mode is sent by one digital output (X2M/4 and X2M/3) on the indoor unit to: The heat pump convectors The shut-off valve EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Human Comfort Interface (BRC1HHDA) or an external room thermostat), while the other rooms are controlled by so-called thermostatic valves, which open or close depending on the room temperature. Setup EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 39
▪ For more information about connecting the electrical wiring to the unit, see: "9.2 Connections to the outdoor unit" [ 100] "9.3 Connections to the indoor unit" [ 107] EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 40
▪ For more information about connecting the electrical wiring to the unit, see: "9.2 Connections to the outdoor unit" [ 100] "9.3 Connections to the indoor unit" [ 107] EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 41
Combination: Underfloor heating + Heat pump convectors – Multiple rooms Setup A Main leaving water temperature zone B Room 1 C Room 2 a External room thermostat b Heat pump convectors (+ controllers) EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 42
▪ #: [2.9] temperature. ▪ Code: [C-07] Number of water temperature zones: 0 (Single zone): Main ▪ #: [4.4] ▪ Code: [7-02] EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
(no real cooling), or NOT allow it. See setup below. Setup Three bizone kit system variations are possible: System without hydraulic separator: System with hydraulic separator for main zone: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 44
This is to guarantee the correct water flow balance between the main leaving water temperature zone and the additional leaving water temperature zone in relation to the required capacity of both water temperature zones. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 45
The user interface integrated in the indoor unit decides the space operation mode. Mind that the operation mode on each controller of the heat pump convectors must be set to match the indoor unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 46
The combination of the two heat emitter systems provides the excellent heating comfort of the underfloor heating, and the excellent cooling comfort of the heat pump convectors. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
During heating operation of the auxiliary boiler, the auxiliary boiler operates to achieve the desired water temperature set via the auxiliary boiler controller. Setup ▪ Integrate the auxiliary boiler as follows: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 48
Make sure the auxiliary boiler and its integration in the system complies with applicable legislation. ▪ Daikin is NOT responsible for incorrect or unsafe situations in the auxiliary boiler system. ▪ Make sure the return water to the heat pump does NOT exceed 60°C. To do so: Set the desired water temperature via the auxiliary boiler controller to maximum 60°C.
Page 49
To prevent freeze-up of the water piping, the auxiliary gas boiler must have a fixed setpoint ≥55°C, or a weather-dependent setpoint ≥T (°C) –30 –25 –20 –15 –10 –5 (°C) Outdoor temperature Minimum weather-dependent setpoint for auxiliary gas boiler EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Example: If the DHW consumption of a family (4 persons) per day is as follows: ▪ 3 showers ▪ 1 bath ▪ 3 sink volumes Then the DHW consumption = (3×100 l)+(1×150 l)+(3×10 l)=480 l EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
6.4.3 Setup and configuration – DHW tank ▪ For large DHW consumptions, you can heat up the DHW tank several times during the day. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
You can program a schedule to control the DHW pump via the user interface. For more information, see the user reference guide. 6.4.5 DHW pump for disinfection Setup EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
▪ The produced heat is calculated internally based on: The leaving and entering water temperature The flow rate EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Backup heater supplied from a single- (*3V, *6V (6V): 1N~ 230 V) phase grid (i.e. the backup heater model is *3V or *6V connected to a single-phase grid) EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 55
NOT have to set which meter covers which power consumption. You only need to set the number of pulses of each power meter. ▪ "6.5.4 Preferential kWh rate power supply" [ 56] for an example with two power meters. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
6.6 Setting up the power consumption control You can use the following power consumption controls. For more information about the corresponding settings, see "Power consumption control" [ 200]. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
DHW production. Power input t Time DI Digital input (power limitation level) a Power limitation active b Actual power input EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
6.6.2 Power limitation activated by digital inputs Power limitation is also useful in combination with an energy management system. The power or current of the entire Daikin system is limited dynamically by digital inputs (maximum four steps). Each power limitation level is set via the user interface by limiting one of the following: ▪...
Produced heat Consumed energy A Outdoor unit B Backup heater a Limited outdoor unit operation b Full outdoor unit operation c Backup heater step 1 turned ON EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
You can connect one external temperature sensor. It measures the indoor or outdoor ambient temperature. We recommend to use an external temperature sensor in the following cases: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 61
To protect the outdoor unit, the internal sensor of the outdoor unit is always used. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Mind the spacing guidelines. See "16.1 Service space: Outdoor unit" [ 254]. NOTICE ▪ Do NOT stack the units on each other. ▪ Do NOT hang the unit on a ceiling. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 63
This is to prevent corrosion caused by high levels of salt in the air, which might shorten the life of the unit. Install the outdoor unit away from direct sea winds. Example: Behind the building. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 64
WARNING Make sure installation, servicing, maintenance and repair comply with instructions from Daikin and with applicable legislation and are executed ONLY by authorised persons. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 –...
Heating only models + conversion kit (EKHVCONV*) ▪ Mind the measurement guidelines: Maximum height difference between indoor unit and outdoor 10 m unit Maximum total water piping length 50 m EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Precise water piping length can be determined using the Hydronic Piping Calculation tool. The Hydronic Piping Calculation tool is part of the Heating Solutions Navigator which can be reached via https://professional.standbyme.daikin.eu. Please contact your dealer if you have no access to Heating Solutions Navigator.
3 Remove the transportation stays (2×), and dispose of them. 7.2.4 To close the outdoor unit NOTICE When closing the outdoor unit cover, make sure that the tightening torque does NOT exceed 4.1 N•m. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
NOTICE If you remove the user interface panel, also disconnect the cables from the back of the user interface panel to prevent damage. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 69
▪ When you need access to the high voltage switch box 2× 5 If you need access to the high voltage components, remove the high voltage switch box cover. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
2 Tilt the switch box to the front and lift it out of its hinges. 2× 3 Place the switch box lower on the unit. Use the 2 hinges located lower on the unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise. Fix the unit securely by means of foundation bolts in accordance with the foundation drawing. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Make sure not to cover the drain hole in the bottom plate of the unit. 7.3.4 To install the outdoor unit 1 Carry the unit by its slings, and put it onto the installation structure. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Install the unit on a base to make sure that there is proper drainage in order to avoid ice accumulation. ▪ Prepare a water drainage channel around the foundation to drain waste water away from the unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 74
O-ring (delivered as accessory) c Drain plug (delivered as accessory) d Hose (field supply) NOTICE O-ring. Make sure the O-ring is installed correctly to prevent leakage. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
4 Align and attach the left side. 5 Align and attach the middle part. 6 Align and attach the right side. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
75] ▪ "7.3.7 To remove the discharge grille, and put the grille in safety position" [ 76] 1 Remove the upper part of the discharge grille. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 77
4 Align the ball stud and hook on the grille with their counterparts on the unit. 5 Insert the hook. 6 Insert the ball stud. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
3 Slide the indoor unit into position. 4 Adjust the height of the leveling feet to compensate for floor irregularities. The maximum allowed deviation is 1°. ≤1° EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
4 Reattach the side panel. Ensure the water can flow through the drain tube. It is recommended to use a tundish to collect the water. Option 1: Through the left side panel 3× EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 80
Unit installation Option 2: Through the right side panel 3× EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Because brass is a soft material, use appropriate tooling for connecting the water circuit. Inappropriate tooling will cause damage to the pipes. ▪ Insulation. Insulate up to the base of the heat exchanger. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 82
The following illustration is an example and might NOT match your system layout. 89°C (*) 75°C (*) 75°C (*) (*) Maximum temperature for piping and accessories EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Recirculation pump 8.1.2 Formula to calculate the expansion vessel pre-pressure The pre-pressure (Pg) of the vessel depends on the installation height difference (H): Pg=0.3+(H/10) (bar) EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
For more information on the addition of glycol, refer to "8.2.6 To protect the water circuit against freezing" [ 91]. Use the following graph to determine the maximum water volume for the calculated pre-pressure. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 85
NOT be displayed on the user interface. In this case, the minimum flow rate can be checked by way of the pump test (check that the user interface does NOT display error 7H). EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Example 2 The indoor unit is installed at the highest point in the water circuit. The total water volume in the water circuit is 250 l. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Deformation of the piping can cause malfunctioning of the unit. Outdoor unit 1 Connect the shut-off valve (with integrated filter) to the outdoor unit water inlet, using thread sealant. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 88
4 Connect the space heating/cooling field piping of both zones to the shut-off valves. 5 Connect the domestic hot water in and out pipes to the indoor unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 89
A pressure relief valve (field supply) with an opening pressure of maximum 10 bar (=1 MPa) must be installed on the domestic cold water inlet connection in accordance with the applicable legislation. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
8.2.5 To fill the water circuit To fill the water circuit, use a field supply filling kit. Make sure you comply with the applicable legislation. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Freeze protection by glycol About freeze protection by glycol Adding glycol to the water lowers the freezing point of water. WARNING Ethylene glycol is toxic. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 92
Add glycol according to the table below. Lowest expected outdoor Prevent from bursting Prevent from freezing temperature –5°C –10°C –15°C –20°C — –25°C — –30°C — EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 93
To protect the field piping against freezing, install the following parts: a Automatic air intake b Freeze protection valve (optional – field supply) c Normally closed valves (recommended – field supply) EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
For piping in free air, it is recommended to use the insulation thickness as shown in below table as a minimum (with λ=0.039 W/mK). EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 95
The Hydronic Piping Calculation tool is part of the Heating Solutions Navigator which can be reached via https://professional.standbyme.daikin.eu. Please contact your dealer if you have no access to Heating Solutions Navigator. This recommendation ensures good operation of the unit, however, local regulations may differ and shall be followed.
DANGER: RISK OF ELECTROCUTION WARNING ALWAYS use multicore cable for power supply cables. INFORMATION Also read the precautions and requirements in the "2 General safety precautions" [ 10]. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Stranded conductor wire b Round crimp-style terminal ▪ Use the following methods for installing wires: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Equipment complying with EN/IEC 61000‑3‑12 (European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤75 A per phase.). EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
5 Normal kWh rate power supply (to power the indoor unit PCB in the event of power supply interruption of the preferential kWh rate power supply) EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
(optional) Drain tube heater cable (field supply) d Cable sleeves (factory-mounted) 4 Inside the switch box, connect the wires to the appropriate terminals, and fix the cables with cable ties. See: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 101
▪ Connect the wires to the terminal block (make sure the numbers match with the numbers on the indoor unit) and the earth screw. ▪ Fix the cable with a cable tie. Wires: (3+GND)×1.5 mm² — EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 102
▪ Fix the cable with cable ties. Wires: (2+GND)×0.75 mm². Wiring must be double insulated. Maximum power allowed for drain tube heater = 115 W (0.5 A) — EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 103
▪ Connect the wires to the terminal block. ▪ Fix the cable with a cable tie. Wires: 3N+GND Maximum running current: Refer to name plate on unit. — EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 104
▪ Connect the wires to the terminal block (make sure the numbers match with the numbers on the indoor unit) and the earth screw. ▪ Fix the cable with a cable tie. Wires: (3+GND)×1.5 mm² — EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 105
▪ Fix the cable with cable ties. Wires: (2+GND)×0.75 mm². Wiring must be double insulated. Maximum power allowed for drain tube heater = 115 W (0.5 A) — EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
9.2.2 To reposition the air thermistor on the outdoor unit This procedure is only necessary in areas with low ambient temperatures. Required accessory (delivered with the unit): Thermistor fixture. Click EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Maximum running current: 100 mA For the main zone: ▪ [2.9] Control ▪ [2.A] Thermostat type For the additional zone: ▪ [3.A] Thermostat type ▪ [3.9] (read-only) Control EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 108
▪ Installation manual of the remote indoor sensor ▪ Addendum book for optional equipment Wires: 2×0.75 mm² [9.B.1]=2 (External sensor = Room) [1.7] Room sensor offset EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 109
You need to connect the multi-zoning base unit to the outdoor unit For cooling/heating operation, you also need to implement a relay (field supply, see addendum book for optional equipment) EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
In case of normal kWh rate power supply Interconnection cable Wires: (3+GND)×1.5 mm² (= main power supply) — 1 2 3 1 2 3 X11YB X11YA X11Y a Interconnection cable (=main power supply) EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 111
Interconnection cable (=main power supply) b Normal kWh rate power supply c Preferential power supply contact 3 Fix the cables with cable ties to the cable tie mountings. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Electrical equipment complying with EN/IEC 61000-3-12 (European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤75 A per phase). EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 113
Connections to backup heater power supply *6V (6V: 1N~ 230 V) Q1DI 1N~, 50 Hz 230 V AC *6V (6T1: 3~ 230 V) Q1DI 3~, 50 Hz L1 L2 L3 230 V AC EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
2 Connect the valve control cable to the appropriate terminals as shown in the illustration below. NOTICE Wiring is different for a NC (normally closed) valve and a NO (normally open) valve. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
2 User interface panel 3 Upper switch box cover 2 Connect the electricity meters cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
2 User interface panel 3 Upper switch box cover 2 Connect the domestic hot water pump cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
2 Connect the alarm output cable to the appropriate terminals as shown in the illustration below. Wires connected to the alarm output Wire between X2M and A4P Installation of EKRP1HBAA is required. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
2 User interface panel 3 Upper switch box cover 2 Connect the space cooling/heating ON/OFF output cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
[9.C] Bivalent 1 Open the following (see "7.2.5 To open the indoor unit" [ 68]): 1 Top panel 2 User interface panel 3 Upper switch box cover EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
2 User interface panel 3 Upper switch box cover 2 Connect the power consumption digital inputs cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
2 Connect the safety thermostat (normally closed) cable to the appropriate terminals as shown in the illustration below. Note: The jumper wire (factory-mounted) must be removed from the respective terminals. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Smart Grid relay kit (EKRELSG). The 2 incoming Smart Grid contacts can activate the following Smart Grid modes: Smart Grid contact Smart Grid operation mode Free running EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 123
1 Open the following (see "7.2.5 To open the indoor unit" [ 68]): 1 Top panel 2 User interface panel 3 Upper switch box cover 2 Connect the wiring as follows: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 124
Contact sides of relays e Jumper (factory-mounted). If you also connect a safety thermostat (Q4L), replace the jumper with the safety thermostat wires. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 125
1 2 3 4 X10M 5 6 9 10 2 Connect the low voltage wiring as follows: X5M.4 X5M.3 1314 3 Connect the high voltage wiring as follows: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
9.4 After connecting the electrical wiring to the indoor unit To prevent water ingress to the switch box, seal the low voltage wiring intake using the sealing tape (delivered as accessory). EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 127
Electrical installation Without low voltage cables With low voltage cables EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
The calculations of the software ▪ What you can see on and do with the user interface You can configure the system via the user interface. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
▪ Confirm the pin code and proceed. Installer pin code The Installer pin code is 5678. Additional menu items and installer settings are now available. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 130
3 Turn the left dial to select the first part of the setting and confirm by pressing the dial. 4 Turn the left dial to select the second part of the setting 01 15 EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Comfort setpoint [5.2] Eco setpoint [5.3] Reheat setpoint [5.4] Hysteresis [5.9] and [5.A] 10.3 Possible screens 10.3.1 Possible screens: Overview The most common screens are as follows: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
26 Feb 2019 22:19 Possible actions on this screen Go through the list of the main menu. Go to the main menu screen. Enable/disable breadcrumbs. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 134
Outdoor unit Indoor unit / domestic hot water tank Floor-standing indoor unit with integrated tank Wall-mounted indoor unit Wall-mounted indoor unit with separated tank Water pressure EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 135
"14.4.1 To display the help text in case of a malfunction" [ 244] for more information. If the corresponding operation (for example: space heating) is not active, the circle is greyed out. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Displays data and information about the Information indoor unit. Installer settings Restriction: Only for the installer. Gives access to advanced settings. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
[2] Main zone screen °C °C – – Room Main zone [3] Additional zone screen [5] Tank temperature screen °C °C – – Tank Additional zone EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Confirm changes and proceed. 10.3.7 Schedule screen: Example This example shows how to set a room temperature schedule in heating mode for the main zone. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 139
To clear the content of the week schedule 1 Select the name of the current schedule. User defined 1 2 Select Delete. Delete Rename Select 3 Select OK to confirm. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 140
In this example, Monday is the first day you programmed. Thus, the last programmed action is valid up to the first action of next Monday. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 141
5 Repeat this action for all other weekdays. — User defined 1 To program the schedule for Saturday and copy it to Sunday 1 Select Saturday. 2 Select Edit. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 142
The schedule name can contain up to 15 characters. 5 Confirm the new name. INFORMATION Not all schedules can be renamed. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Examples Weather-dependent curve when slope is selected: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 145
The icon corresponds to the heat emitter for that zone: ▪ : Underfloor heating ▪ : Fan coil unit ▪ : Radiator ▪ : Domestic hot water tank EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Go to … Main zone – Heating [2.5] Main zone > Heating WD curve Main zone – Cooling [2.6] Main zone > Cooling WD curve EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
No: Room temperature is directly controlled by the user. ▪ Yes: Room temperature is controlled by a schedule and can be modified by the user. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 149
Antifrost function via the backup heater. If the backup heater is not allowed for room frost protection during a U4 error, the room Antifrost setting MUST be disabled. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 150
Room frost protection is guaranteed by the normal logic. ▪ The external room thermostat is "Thermo ON" In case of 2 leaving water temperature zones: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 151
NOTICE When adjusting the room temperature ranges, all desired room temperatures are also adjusted to guarantee they are between the limits. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
[9-0A] Heating comfort setpoint ▪ [3-07]~[3-06]°C [1.9.2] [9-0B] Cooling comfort setpoint ▪ [3-09]~[3-08]°C 10.5.3 Main zone Overview The following items are listed in the submenu: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 153
Define a heating temperature schedule for the main zone via [2.2] Heating schedule. "10.3.7 Schedule screen: Example" [ 138]. Cooling schedule Define a cooling temperature schedule for the main zone via [2.3] Cooling schedule. "10.3.7 Schedule screen: Example" [ 138]. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 154
10°C. Heating WD curve Set weather-dependent heating for the main zone (if [2.4]=1 or 2): EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 155
Note: This value should be lower than [1‑02] as for high outdoor temperatures less warm water is required. Cooling WD curve Set weather-dependent cooling for the main zone (if [2.4]=2): EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 156
It is important to set Emitter type correctly and in accordance with your system layout. The target delta T for the main zone depends on it. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 157
Example underfloor heating: 40–5/2=37.5°C To compensate, you can: ▪ Increase the weather-dependent curve desired temperatures [2.5]. ▪ Enable leaving water temperature modulation and increase the maximum modulation [2.C]. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 158
Heating maximum: ▪ [2‑0C]=2 (emitter type main zone = radiator) 37°C~70°C ▪ Else: 37°C~55°C [2.8.3] [9-03] Cooling minimum: ▪ 5°C~18°C [2.8.4] [9-02] Cooling maximum: ▪ 18°C~22°C EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 159
Leaving water temperature: Delta T In heating for the main zone, the target delta T (temperature difference) depends on the selected emitter type for the main zone. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 160
Additionally, also the desired leaving water temperature must be configured: if Modulation is enabled, the unit automatically calculates the desired leaving water temperature. These calculations are based on: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 161
1 leaving water temperature zone, connect the shut-off valve to the heating/cooling output. The shut off valve for the main leaving water temperature zone can close under these circumstances: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
143] and "10.4.3 Slope-offset curve" [ 144]. Code Description [2.E] ▪ 2-points ▪ Slope-Offset 10.5.4 Additional zone Overview The following items are listed in the submenu: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 163
138]. Setpoint mode The setpoint mode of the additional zone can be independently set from the setpoint mode of the main zone. "Setpoint mode" [ 154]. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 164
Note: This value should be lower than [0‑01] as for high outdoor temperatures less warm water is required. Cooling WD curve Set weather-dependent cooling for the additional zone (if [3.4]=2): EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 165
[9‑05]~[9‑06] [1‑0C] 0: Underfloor Maximum 55°C Variable (see [3.B.1]) heating 1: Fancoil unit Maximum 55°C Variable (see [3.B.1]) 2: Radiator Maximum 70°C Fixed 10°C EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 166
(X2M/35a) ▪ 2: 2 contacts. Connected to 2 digital inputs (X2M/34a and X2M/35a) Leaving water temperature: Delta T For more information, see "10.5.3 Main zone" [ 152]. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
If your unit is a heating/cooling model, it can both heat up and cool down a space. You have to tell the system which operation mode to use. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 168
To restrict automatic changeover according to a schedule Conditions: You set the space operation mode to Automatic. 1 Go to [4.2]: Space heating/cooling > Operation mode schedule. 2 Select a month. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 169
Besides the desired heating/cooling room temperature, the installer sets a hysteresis value (e.g. when in heating, this EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 170
INFORMATION Mixing station. If your system layout contains 2 LWT zones, you need to install a mixing station in front of the main LWT zone. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 171
Make sure you set the emitter types for the main zone [2.7] and for the additional zone [3.7] correctly in accordance with the connected emitter. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 172
Sample is ONLY available in leaving water temperature control. a Space heating/cooling control b Off c On d LWT temperature e Actual f Desired g Pump operation EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 173
Possible values: see below. [4.8.2] [9-0D] Restriction: Only displayed when the bizone kit (EKMIKPOA or EKMIKPHA) is installed. Pump limitation Additional zone Possible values: see below. Possible values: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 174
The maximum values depend on the unit type: [9-0D]/[9-0E]=0 [9-0D]/[9-0E]=1/5 a (kPa) a (kPa) b (l/min) b (l/min) [9-0D]/[9-0E]=2/6 [9-0D]/[9-0E]=3/7 a (kPa) a (kPa) b (l/min) b (l/min) EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
[5.5] Schedule [5.6] Heat up mode [5.7] Disinfection [5.8] Maximum [5.9] Hysteresis [5.A] Hysteresis [5.B] Setpoint mode [5.C] WD curve [5.D] Margin [5.E] WD curve type EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 177
The storage economic temperature denotes the lower desired tank temperature. It is the desired temperature when a storage economic action is scheduled (preferably during day). EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 178
CAUTION The disinfection function settings MUST be configured by the installer according to the applicable legislation. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 179
CAUTION Be sure that the disinfection function start time [5.7.3] with defined duration [5.7.5] is NOT interrupted by possible domestic hot water demand. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 180
The minimum ON temperature is 20°C, even if setpoint hysteresis is smaller than 20°C. Code Description [5.9] [6-00] Heat pump ON hysteresis ▪ 2°C~40°C EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 181
(according to the weather dependent curve). During weather dependent operation, the end-user cannot adjust the desired tank temperature on the user interface. Also see "10.4 Weather-dependent curve" [ 143]. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 182
Maximum heat pump temperature at sensor in domestic hot water tank HP MAX Heat pump OFF temperature (T −[6-01]) HP OFF HP MAX Heat pump ON temperature (T −[6-00]) HP ON HP OFF EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
[7] User settings Space heating/cooling Tank [7.1] Language User settings [7.2] Time/date Information Installer settings [7.3] Holiday [7.4] Quiet [7.5] Electricity price [7.6] Gas price EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 184
▪ Select On. 2 Set the first day of your holiday. — ▪ Go to [7.3.2]: From. ▪ Select a date. ▪ Confirm the changes. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 185
Go to [7.4.3] Level and select the applicable quiet mode level. Example: Most quiet. Result: The unit always runs in the selected quiet mode level. The user cannot change this. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 186
INFORMATION Price value ranging from 0.00~990 valuta/kWh (with 2 significant values). INFORMATION If no schedule is set, the Electricity price for High is taken into account. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 187
Renewable heat incentive per kWh Calculation of the gas price Gas price=Actual gas price+(Incentive/kWh×0.9) Gas price=4.08+(5×0.9) Gas price=8.58 Calculation of the electricity price Electricity price=Actual electricity price+Incentive/kWh EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
In menu… You can read out… [8.1] Energy data Produced energy, consumed electricity, and consumed gas [8.2] Malfunction history Malfunction history [8.3] Dealer information Contact/helpdesk number EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
[9.D] Alarm output [9.E] Auto restart [9.F] Power saving function [9.G] Disable protections [9.H] Forced defrost [9.I] Overview field settings [9.N] Export MMI settings [9.P] Bizone kit EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 190
When turned on, the pump runs and makes sure hot water is instantly available at the tap. To save energy, only turn on the pump during periods of the day when instant hot water is necessary. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 191
[6‑03]+[6‑04]. INFORMATION If [4‑0A]=3 and emergency mode is active, the power usage of the backup heater is maximal and equal to 2×[6‑03]+[6‑04]. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 192
Only for systems with integrated domestic hot water tank: If the storage temperature setpoint is higher than 50°C, Daikin recommends NOT to disable the backup heater second step because it will have a big impact on the required time for the unit to heat up the domestic hot water tank.
Page 193
NOT confirm emergency operation. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 194
[5‑01] Equilibrium temperature and [5‑03] Space heating priority temperature are related to backup heater. So, you must set [5‑03] equal or a few degrees higher than [5‑01]. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 195
[8-04]. Range: 0~10 hours Remark: The minimum time is 0.5 hours even when the selected value is 0. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 196
ONLY disable water pipe freeze prevention if glycol is used. For more information on freeze protection by glycol, see "8.2.6 To protect the water circuit against freezing" [ 91]. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 197
Therefore, always enable the auto restart function. ▪ 3 Smart grid: A Smart Grid is connected to the system EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 198
Yes: The extra energy from the photovoltaic panels is buffered in the DHW tank, and in the space heating/cooling circuit (i.e. heat up or cool down the room). EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 199
The safety functions (water pipe freeze prevention, drain prevention, room frost protection, tank disinfection) and defrost are NOT overruled (capacity will not be limited for these functions) Recommended on: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 200
Limit when [9.9.1]=Continuous and [9.9.2]=Amp: Code Description [9.9.3] [5-05] Limit: Only applicable in case of full time current limitation mode. 0 A~50 A Limits when [9.9.1]=Inputs and [9.9.2]=Amp: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 201
Note: In case power consumption control is DISABLED (for all models) the setting [4‑01] defines whether backup heater and booster heater can operate simultaneously, or if the booster heater/backup heater has priority over the backup heater/booster heater. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 203
Code Description [9.B.2] [2-0B] Ext. amb. sensor offset: Offset on the ambient temperature measured on the external outdoor temperature sensor. ▪ –5°C~5°C, step 0.5°C EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 204
If Bivalent is disabled: Space heating is only done by the heat pump within the operation range. The permission signal for the auxiliary boiler is always inactive. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 205
To determine the value of [C‑03], proceed as follows: 1 Determine the COP (= coefficient of performance) using the formula: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 206
User settings > Electricity price > [7.6] User settings > Gas price Boiler efficiency Depending on the used boiler, this should be chosen as follows: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 207
Code Description [9.E] [3-00] Auto restart: ▪ 0: Manual ▪ 1: Automatic EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 208
1: Yes Forced defrost Forced defrost Manually start a defrost operation. Code Description [9.H] Do you want to start a defrost operation? ▪ Back ▪ EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 209
2 On the user interface, go to [9.N] Export MMI settings. 3 Select OK. 4 Remove the USB memory stick and close the user interface — panel. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 210
Additional zone pump fixed PWM The speed of the additional zone pump can be fixed with this setting. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
About commissioning See: "11 Commissioning" [ 218] 10.5.11 User profile [B] User profile: See "To change the user permission level" [ 129]. Installer settings Commissioning User profile Operation Malfunctioning EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
[D.4] Device info About the WLAN cartridge The WLAN cartridge connects the system to the internet. The user you can then control the system via the Daikin Residential Controller app. This needs the following components: WLAN cartridge The WLAN cartridge needs to be inserted in the user interface.
Page 213
See: http://www.onlinecontroller.daikineurope.com/ Configuration To configure the Daikin Residential Controller app, follow the in-app instructions. While doing this, the following actions and information are needed on the user interface: Mode: Turn AP mode ON (= WLAN adapter active as access point) or OFF.
Page 214
Configuration Code Description [D.6] Cloud connection: ▪ Not connected ▪ Connected EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
(**) Only accessible by installer (***) Only applicable when WLAN is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
(*) Only applicable in Swedish language. INFORMATION Solar kit settings are shown but are NOT applicable for this unit. Settings shall NOT be used or changed. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 217
Configuration INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
11 Commissioning NOTICE General commissioning checklist. Next to the commissioning instructions in this chapter, a general commissioning checklist is also available on the Daikin Business Portal (authentication required). The general commissioning checklist is complementary to the instructions in this chapter and can be used as a guideline and reporting template during the commissioning and hand-over to the user.
There are NO damaged components or squeezed pipes on the inside of the indoor and outdoor units. Backup heater circuit breaker F1B (field supply) is turned ON. The correct pipe size is installed and the pipes are properly insulated. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
— reach the minimum required flow rate + 2 l/min. During pump test run, the unit can operate below the minimum required flow rate. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
3 In the menu, set Type = Manual. 4 Select Start air purge. 5 Select OK to confirm. Result: The air purge starts. It stops automatically when ready. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
"To change — the user permission level" [ 129]. 2 Go to [A.1]: Commissioning > Operation test run. 3 Select a test from the list. Example: Heating. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
1 In the menu, go to Stop test run. 2 Select OK to confirm. Possible actuator test runs ▪ Backup heater 1 test ▪ Backup heater 2 test ▪ Pump test EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
The installer can program up to 20 steps. For each step he needs to enter: 1 the duration in hours, up to 72 hours, 2 the desired leaving water temperature, up to 55°C. Example: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 225
[2‑06] to "0", and KEEP it disabled until the screed dryout has finished. Ignoring this notice will result in cracking of the screed. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 226
In case of a power failure, the U3 error is not generated. When power is restored, the unit automatically restarts the latest step and continues the program. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 227
If the UFH screed dryout program was stopped due to a power failure and the power resumes, the program will automatically restart the last implemented step. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Show the user what to do for the maintenance of the unit. ▪ Explain the user about energy saving tips as described in the operation manual. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Before performing any maintenance or service work, touch a metal part of the unit in order to eliminate static electricity and to protect the PCB. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Switch box ▪ Descaling ▪ Chemical disinfection 13.3.4 Yearly maintenance indoor unit: instructions Water pressure Keep water pressure above 1 bar. If it is lower, add water. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 231
"13.5.3 To install the water filter" [ 235] Water pressure relief valve Open the valve and check if it operates correctly. The water may be very hot! Checkpoints are: EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 232
For this reason, descaling of the heat exchanger may be required at certain intervals. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
▪ "13.5.1 To remove the water filter" [ 234] ▪ "13.5.2 To clean the water filter in case of trouble" [ 234] ▪ "13.5.3 To install the water filter" [ 235] EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Opening the magnetic filter/dirt separator is ONLY required in case of severe issues. Preferably this action is never to be done during the complete lifetime of the magnetic filter/dirt separator. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Check the condition of the O-rings and replace if needed. Apply water to the O-rings before installation. 1 Install the water filter in the correct location. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 236
Make sure to open the valve (if equipped) towards the expansion vessel, otherwise the overpressure will be generated. 5 Open the stop valves and add water to the water circuit if needed. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
If you are unable to find the cause of the problem, call your dealer. DANGER: RISK OF ELECTROCUTION EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Make sure that the water volume in the too low installation is above the minimum required value (see "8.1.3 To check the water volume and flow rate" [ 84]). EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Perform hydraulic balancing to assure that the flow is correctly distributed between the emitters. hydraulic balancing sufficient, change pump limitation settings ([9-0D] and [9-0E] if applicable). EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Purge air manually (see "To perform a manual air purge" [ 221]) or use the automatic air purge function (see "To perform an automatic air purge" [ 222]). EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
0 m. The maximum water circuit head is 10 m. Check the installation requirements. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
> Backup heater > Equilibrium temperature [5‑01] There is air in the system. Purge air manually or automatically. See the air purge function in the chapter "11 Commissioning" [ 218]. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
The disinfection operation was stopped Do NOT stop tank operation during manually: [C.3] Operation > Tank was disinfection. turned off during disinfection. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Leaving water temperature sensor problem 81-01 Mixed water thermistor abnormality. 81-06 Entering water temperature thermistor abnormality (indoor unit) 89-01 Heat exchanger freeze-up protection activated during defrost (error) EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 245
OU: Overheat of inverter compressor motor E6-00 OU: Compressor startup defect E7-00 OU: Malfunction of outdoor unit fan motor E8-00 OU: Power input overvoltage E9-00 Malfunction of electronic expansion valve EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 246
JC-01 Evaporator pressure abnormality L1-00 Malfunction of INV PCB L3-00 OU: Electrical box temperature rise problem L4-00 OU: Malfunction of inverter radiating fin temperature rise EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 247
Indoor unit, outdoor unit matching problem UA-16 Extension/hydro communication problem UA-17 Tank type problem UA-21 Extension/hydro mismatch problem UF-00 Reversed piping or bad communication wiring detection EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 248
If the software is not successfully updated then you must make sure that your USB device has the FAT32 format. INFORMATION The user interface will display how to reset an error code. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
76] 1 Make sure the unit is not running. 2 Activate the recovery mode (see "15.1.2 Recovery mode" [ 251]). Result: The unit opens the valves (Y*). EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
3 Turn the EEV magnet anticlockwise to the fully open position of the valve. If you are not sure about what the open position is, turn the valve in its middle position so that refrigerant can pass. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Press BS3 once. Press BS2 once. Press BS3 once. Press BS3 once. The flashing H1P indicates the recovery mode has been correctly selected and is activated. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 252
/ solenoid valves to their initial state. INFORMATION Power OFF. When power is turned OFF and turned ON again, the recovery mode is deactivated automatically. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Technical data 16 Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). In this chapter 16.1...
Right side view See note *** See note *** Notes: Symbols: Live Neutral Protective earth Noiseless earth Field wiring Option Terminal strip Terminal Connector Connection EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 258
Light-emitting diode (service monitor is orange) HAP (A1P) Light-emitting diode (service monitor is green) K1R (A1P) Magnetic relay (Y1S) K1R (A4P) Magnetic relay (E1HHEX~E3HHEX) K2R (A1P) Magnetic relay (Y2S) EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 263
Relay on PCB # Domestic hot water pump # 2-way valve for cooling mode PC (A15P) * Power circuit PHC1 (A4P) * Optocoupler input circuit EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 264
Use normal kWh rate power supply for indoor unit indoor unit (2) Backup heater power supply (2) Backup heater power supply Only for *** Only for *** EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 265
(7) Option PCBs Alarm output Alarm output Changeover to ext. heat source Changeover to external heat source Max. load Maximum load Min. load Minimum load EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 266
Only for heat pump convector Only for wired On/OFF thermostat Only for wired On/OFF thermostat Only for wireless On/OFF thermostat Only for wireless On/OFF thermostat EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Page 267
A3P: X11M: 3-4-5-6 signal main & add: X2M: 3-4 Only for Human Comfort Interface 2 core 2×0.75 X5M: 11-12 A14P: P1-P2 user interface communication 4D133216A EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
See also the minimum and maximum allowed water flow range in the technical specifications. ▪ Water quality must be according to EU directive 98/83 EC. EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W Installer reference guide Daikin Altherma 3 H HT F 4P644737-1 – 2021.02...
Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
Page 271
2/13 Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value Room └─ Antifrost 1.4.1 [2-06] Activation 0: Disabled 1: Enabled 1.4.2 [2-05] Room setpoint 4~16°C, step: 1°C 8°C └─...
Page 272
3/13 Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value 2.C.2 [8-06] Max modulation 0~10°C, step: 1°C 5°C └─ Shut off valve 2.D.1 [F-0B] During thermo 0: No 1: Yes 2.D.2 [F-0C]...
Page 273
4/13 Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value [9-04] Overshoot 1~4°C, step: 1°C 1°C [2-06] Antifrost 0: Disabled 1: Enabled Tank [6-0A] Comfort setpoint 30~[6-0E]°C, step: 1°C 60°C [6-0B] Eco setpoint...
Page 274
5/13 Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value 9.1.3.4 [4-06] Emergency 0: Manual 1: Automatic 2: Auto red SH/ DHW ON 3: Auto red SH/ DHW OFF 4: Auto normal SH/ DHW OFF 9.1.3.5 [7-02]...
Page 275
6/13 Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value 9.1.A [0-07] Low ambient temp. for LWT add zone cooling WD curve. 10~25°C, step: 1°C 20°C └─ Tank 9.1.B.1 [6-0D] Heat up mode...
Page 276
7/13 Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value 9.8.6 Allow electric heaters 0: No 1: Yes 9.8.7 Enable Room buffering 0: No 1: Yes 9.8.8 Limit setting kW 0~20 kW, step: 0,5 kW 20 kW └─...
Page 277
8/13 Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value [0-06] High ambient temp. for LWT add zone cooling WD curve. 25~43°C, step: 1°C 35°C [0-07] Low ambient temp. for LWT add zone cooling WD curve. 10~25°C, step: 1°C 20°C [0-0B]...
Page 278
9/13 Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value [3-00] Is auto restart of the unit allowed? 0: No 1: Yes [3-01] [3-02] [3-03] [3-04] [3-05] [3-06] What is the maximum desired room temperature in heating? 18~30°C, step: 1°C 30°C...
Page 279
10/13 Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value [6-09] [6-0A] What is the desired comfort storage temperature? 30~[6-0E]°C, step: 1°C 60°C [6-0B] What is the desired eco storage temperature? 30~min(50, [6-0E])°C, step: 1°C 45°C [6-0C]...
Page 280
11/13 Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value [9-0A] What is the room buffering temperature in heating? [3-07]~[3-06]°C, step: 0,5°C 23°C [9-0B] What is the room buffering temperature in Cooling? [3-09]~[3-08]°C, step: 0,5°C 23°C [9-0C]...
Page 281
12/13 Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value [E-07] What kind of DHW tank is installed? 0: EKHW, small volume (*3) 1: Integrated (*4) 3: EKHW, large volume 5: EKHWP (*3) 7: Third party tank, small coil 8: Third party tank, large coil...
Need help?
Do you have a question about the ETVH16S18EA6V and is the answer not in the manual?
Questions and answers