Sign In
Upload
Manuals
Brands
Daikin Manuals
Heat Pump
Altherma EHYHBH05A Series
User Manuals: Daikin Altherma EHYHBH05A Series Pump
Manuals and User Guides for Daikin Altherma EHYHBH05A Series Pump. We have
1
Daikin Altherma EHYHBH05A Series Pump manual available for free PDF download: Installer's Reference Manual
Daikin Altherma EHYHBH05A Series Installer's Reference Manual (264 pages)
Hybrid heat pump
Brand:
Daikin
| Category:
Heat Pump
| Size: 13 MB
Table of Contents
Table of Contents
2
About the Product
6
About this Document
8
Meaning of Warnings and Symbols
8
Installer Reference Guide at a Glance
10
General Safety Precautions
12
For the Installer
12
General
12
Installation Site
13
Refrigerant - in Case of R410A or R32
14
Water
16
Electrical
16
Gas
18
Gas Exhaust
19
Local Legislation
19
Specific Installer Safety Instructions
21
About the Box
28
Outdoor Unit
28
To Unpack the Outdoor Unit
28
To Remove the Accessories from the Outdoor Unit
29
Indoor Unit
30
To Unpack the Indoor Unit
30
To Remove the Accessories from the Indoor Unit
31
Gas Boiler
31
To Unpack the Gas Boiler
31
To Remove the Accessories from the Gas Boiler
32
About the Units and Options
34
Identification
34
Identification Label: Outdoor Unit
34
Identification Label: Indoor Unit
35
Identification Label: Gas Boiler
35
Combining Units and Options
37
Possible Options for the Outdoor Unit
37
Possible Options for the Indoor Unit
38
Possible Options for the Gas Boiler
41
Possible Combinations of Indoor Unit and Outdoor Unit
46
Possible Combinations of Indoor Unit and Domestic Hot Water Tank
47
Unit Installation
48
Preparing the Installation Site
48
Installation Site Requirements of the Outdoor Unit
49
Additional Installation Site Requirements of the Outdoor Unit in Cold Climates
50
Installation Site Requirements of the Indoor Unit
51
Opening and Closing the Units
52
About Opening the Units
52
To Open the Outdoor Unit
52
To Open the Switch Box Cover of the Indoor Unit
53
To Open the Gas Boiler
54
To Open the Switch Box Cover of the Gas Boiler
54
To Close the Outdoor Unit
55
To Close the Indoor Unit
55
To Close the Gas Boiler
55
To Install the Gas Boiler Cover Plate
56
Mounting the Outdoor Unit
56
About Mounting the Outdoor Unit
56
Precautions When Mounting the Outdoor Unit
57
To Provide the Installation Structure
57
To Install the Outdoor Unit
59
To Provide Drainage
60
To Prevent the Outdoor Unit from Falling over
61
Mounting the Indoor Unit
62
About Mounting the Indoor Unit
62
Precautions When Mounting the Indoor Unit
62
To Install the Indoor Unit
62
Mounting the Gas Boiler
63
To Install the Gas Boiler
63
To Install the Condensate Trap
65
Connecting the Boiler to the Flue Gas System
66
To Change the Gas Boiler to 80/125 Concentric Connection
67
To Change the 60/100 Concentric Connection to a Dual Pipe Connection
68
Calculate the Total Piping Length
69
Appliance Categories and Pipe Lengths
70
Applicable Materials
74
Flue Pipe Position
75
Insulation of the Gas Exhaust and Air Intake
76
Fitting a Horizontal Flue System
76
Fitting a Vertical Flue System
77
Plume Management Kit
77
Flues in Voids
78
Flue Gas Materials (C63) Available on the Market
79
About Securing the Flue System
80
Condensate Pipe Work
81
Internal Connections
82
External Connections
83
Piping Installation
84
Preparing Refrigerant Piping
84
Refrigerant Piping Requirements
84
Refrigerant Piping Insulation
85
Connecting the Refrigerant Piping
85
About Connecting the Refrigerant Piping
85
Precautions When Connecting the Refrigerant Piping
86
Guidelines When Connecting the Refrigerant Piping
87
Pipe Bending Guidelines
87
To Flare the Pipe End
87
To Braze the Pipe End
88
Using the Stop Valve and Service Port
89
To Connect the Refrigerant Piping to the Outdoor Unit
90
To Connect the Refrigerant Piping to the Indoor Unit
91
Checking the Refrigerant Piping
91
About Checking the Refrigerant Piping
91
Precautions When Checking the Refrigerant Piping
92
To Check for Leaks
92
To Perform Vacuum Drying
92
To Insulate the Refrigerant Piping
93
Charging Refrigerant
94
About Charging Refrigerant
94
Precautions When Charging Refrigerant
95
To Determine the Additional Refrigerant Amount
95
To Determine the Complete Recharge Amount
95
To Charge Additional Refrigerant
95
To Fix the Fluorinated Greenhouse Gases Label
96
Preparing Water Piping
96
Water Circuit Requirements
96
Formula to Calculate the Expansion Vessel Pre-Pressure
99
To Check the Water Volume and Flow Rate
100
Changing the Pre-Pressure of the Expansion Vessel
102
To Check the Water Volume: Examples
103
Connecting Water Piping
103
About Connecting the Water Piping
103
Precautions When Connecting the Water Piping
103
Connecting the Water Piping of the Indoor Unit
104
Connecting the Water Piping of the Gas Boiler
105
To Fill the Space Heating Circuit
106
To Fill the Domestic Water Circuit of the Gas Boiler
107
To Fill the Domestic Hot Water Tank
107
To Insulate the Water Piping
107
Connecting the Gas Piping
108
To Connect the Gas Pipe
108
To Perform an Air Purge on the Gas Supply
108
Electrical Installation
110
About Connecting the Electrical Wiring
110
Precautions When Connecting the Electrical Wiring
111
Guidelines When Connecting the Electrical Wiring
111
Overview of Electrical Connections Except External Actuators
113
Overview of Electrical Connections for External and Internal Actuators
114
About Preferential Kwh Rate Power Supply
115
Connections to the Outdoor Unit
116
To Connect the Electrical Wiring to the Outdoor Unit
116
Connections to the Indoor Unit
117
To Connect the Electrical Wiring to the Indoor Unit
117
To Connect the Main Power Supply of the Indoor Unit
118
To Connect the Main Power Supply of the Gas Boiler
120
To Connect the Communication Cable between Gas Boiler and Indoor Unit
120
To Connect the User Interface
122
To Connect the Shut-Off Valve
124
To Connect the Electrical Meter
125
To Connect the Gas Meter
125
To Connect the Domestic Hot Water Pump
125
To Connect the Alarm Output
126
To Connect the Space Cooling/Heating ON/OFF Output
126
To Connect the Power Consumption Digital Inputs
127
To Connect the Safety Thermostat (Normally Closed Contact)
127
Configuration
129
Indoor Unit
129
Overview: Configuration
129
Basic Configuration
134
Advanced Configuration/Optimisation
154
Menu Structure: Overview User Settings
177
Menu Structure: Overview Installer Settings
179
Gas Boiler
180
Overview: Configuration
180
Basic Configuration
180
Operation
190
Overview: Operation
190
Heating
190
Domestic Hot Water
190
Flow Resistance Graph for Appliance Domestic Hot Water Circuit
191
Operation Modes
191
Commissioning
194
Overview: Commissioning
194
Precautions When Commissioning
195
Checklist before Commissioning
195
Checklist During Commissioning
196
To Check the Minimum Flow Rate
197
Air Purge Function
197
To Perform a Test Run
199
To Perform an Actuator Test Run
200
Underfloor Heating Screed Dryout
201
To Perform a Gas Pressure Test
204
To Perform a Test Run on the Gas Boiler
204
Hand-Over to the User
206
Maintenance and Service
207
Maintenance Safety Precautions
207
Opening the Indoor Unit
207
Checklist for Yearly Maintenance of the Outdoor Unit
207
Checklist for Yearly Maintenance of the Indoor Unit
208
To Disassemble the Gas Boiler
209
To Clean the Inside of the Gas Boiler
212
To Assemble the Gas Boiler
213
Troubleshooting
215
Overview: Troubleshooting
215
Precautions When Troubleshooting
215
Solving Problems Based on Symptoms
216
Symptom: the Unit Is NOT Heating or Cooling as Expected
216
Symptom: the Compressor Does NOT Start (Space Heating or Domestic Water Heating)
217
Symptom: the Pump Is Making Noise (Cavitation)
217
Symptom: the Pressure Relief Valve Opens
218
Symptom: the Water Pressure Relief Valve Leaks
218
Symptom: the Space Is NOT Sufficiently Heated at Low Outdoor Temperatures
218
Symptom: the Pressure at the Tapping Point Is Temporarily Unusually High
219
Symptom: Tank Disinfection Function Is NOT Completed Correctly (AH-Error)
219
Symptom: Boiler Abnormality Detection (HJ-11 Error)
220
Symptom: Boiler/Hydrobox Combination Abnormality (UA-52 Error)
220
Symptom: the Burner Does NOT Ignite
220
Symptom: the Burner Ignites Noisily
221
Symptom: the Burner Resonates
221
Symptom: no Space Heating by the Gas Boiler
222
Symptom: the Power Is Reduced
222
Symptom: Space Heating Does NOT Reach the Temperature
222
Symptom: Hot Water Does NOT Reach the Temperature (no Tank Installed)
222
Symptom: Hot Water Does NOT Reach the Temperature (Tank Installed)
223
Solving Problems Based on Error Codes
223
Error Codes: Overview
223
Disposal
232
Overview: Disposal
232
To Pump down
232
To Start and Stop Forced Cooling
233
Technical Data
234
Piping Diagram: Outdoor Unit
234
Piping Diagram: Indoor Unit
235
Wiring Diagram: Outdoor Unit
236
Wiring Diagram: Indoor Unit
237
Wiring Diagram: Gas Boiler
243
ESP Curve: Indoor Unit
244
Technical Specifications: Gas Boiler
245
General
245
Energy-Related Products Specifications
247
Appliance Category and Supply Pressure
248
Glossary
252
Field Settings Table
253
Advertisement
Advertisement
Related Products
Daikin EHYHBH05AA
Daikin EHYHBH08AA
Daikin Altherma EHYHBH05AF
Daikin Altherma EHYHBH/X08AF
Daikin Altherma EHYHBH-AV32 Series
Daikin Altherma EHYHBH08AF
Daikin Altherma EHYHBH-AV3
Daikin Altherma EHYHBH/X08A Series
Daikin EHYHBX08AA
Daikin Altherma EHYHBX-AV32 Series
Daikin Categories
Air Conditioner
Heat Pump
Chiller
Remote Control
Air Handlers
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL