Daikin E-Series Service Manual page 148

Hide thumbs Also See for E-Series:
Table of Contents

Advertisement

SiAU18-715
Caution
DIP switch Setting after changing the main PCB(A1P) to spare parts PCB
When you change the main PCB(A1P) to spare parts PCB, please carry out the following setting.
Please Attach the Capacity Setting Adapter corresponding to Capacity Class (ex. 112, 140, 160) in connector X51A.
(See Below)
Capacity Setting Adapter
Position of Attaching the Capacity Setting Adapter
X51A
Position of Attaching
the Capacity Setting Adapter
Test Operation
Capacity Class
CAPACITY SETTING ADAPTER (for 100/J112)
4 (112)
5 (140)
CAPACITY SETTING ADAPTER (for 125/J140)
6 (160)
CAPACITY SETTING ADAPTER (for 140/J160)
Note
Field Setting
135