9 Settings
Fig.57
° C
3
47
44
41
38
35
32
29
26
23
20
00:00
00:00
00:00
2
10
9
8
7
6
1
Tab.29
Example: Adjustment of the temperature setting every 7 days
Days
Start temperature
1 to 7
+25 °C
8 to 14
+55 °C
15 to 21
+55 °C
9.4

Configuring the maintenance message

Type of notification:
None
Custom notification
ABC notification
9.5

Saving the installer details

9.6

Saving the commissioning settings

46
MID _HMI T-control - Gas 120 ACE
5
4
3
2
1
End temperature
+55 °C
+55 °C
+25 °C
On
Description
No maintenance message
The maintenance message will be displayed once the burner operating hours defined
by the Service Burning hrs parameter have elapsed
Recommended setting
The maintenance message will be displayed according to the power input (energy val­
ue):
Gas 120 ACE - 65 : 90,000 kWh
Gas 120 ACE - 90 : 135,000 kWh
Gas 120 ACE - 115 : 180,000 kWh
On
On
3. Set the following parameters:
Parameters
Description
Zone screed drying
Number of days of drying (1)
ScreedStartTemp
Drying start temperature (2)
ScreedStopTemp
Drying end temperature (3)
The screed drying programme will start immediately and continue for the
selected number of days.
At the end of the programme, the selected operating mode will restart.
Temperature variation
Temperature increased every day by 5 °C
Temperature maintained at +55 °C without dropping at night
Temperature decreased every day by 5 °C
The boiler control panel is used to display a message whenever a service
is necessary.
To configure the maintenance message:
1. Select the Maintenance
2. Select Service notification.
3. Select the desired type of notification:
The name and phone number of the installer can be saved so that the
user can find it easily.
1. Press the
key.
2. Select System Settings > Installer Details.
3. Enter the name and phone number.
You can save all installation-specific settings. These settings can be
restored if necessary, for example after replacement of the main electronic
control system board.
1. Press the
key.
2. Select Advanced Service Menu > Save as commissioning settings.
3. Select Confirm to save the settings.