E: Motor Parameters; E: Motor Parameters; E1: V/F Pattern For Motor 1 - YASKAWA Z1000 User Manual

Hide thumbs Also See for Z1000:
Table of Contents

Advertisement

B.5 E: Motor Parameters
B.5 E: Motor Parameters
u

E1: V/f Pattern for Motor 1

No.
(Addr.
Name
Hex)
E1-01
Input Voltage Setting
(300)
E1-03
V/f Pattern Selection
(302)
E1-04
Maximum Output
(303)
Frequency
E1-05
Maximum Voltage
(304)
E1-06
Base Frequency
(305)
E1-07
Middle Output
(306)
Frequency
E1-08
Middle Output
(307)
Frequency Voltage
E1-09
Minimum Output
(308)
Frequency
E1-10
Minimum Output
(309)
Frequency Voltage
E1-11
Middle Output
(30A)
Frequency 2
<6>
E1-12
Middle Output
(30B)
Frequency Voltage 2
<6>
E1-13
Base Voltage
(30C)
296
LCD Display
This parameter must be set to the power supply voltage.
WARNING! Electrical Shock Hazard. Drive input voltage
(not motor voltage) must be set in E1-01 for the protective
Input Voltage
features of the drive to function properly. Failure to do so
may result in equipment damage and/or death or personal
injury.
V/F Selection
0: 50 Hz, Constant torque 1
0: 50 Hz
1: 60 Hz, Constant torque 2
1: 60 Hz Saturation
2: 60 Hz, Constant torque 3 (50 Hz base)
2: 60 Hz Saturation
3: 72 Hz, Constant torque 4 (60 Hz base)
3: 72 Hz
4: 50 Hz, Variable torque 1
4: 50 Hz VT1
5: 50 Hz, Variable torque 2
5: 50 Hz VT2
6: 60 Hz, Variable torque 3
6: 60 Hz VT1
7: 60 Hz, Variable torque 4
7: 60 Hz VT2
8: 50 Hz, High starting torque 1
8: 50 Hz HST1
9: 50 Hz, High starting torque 2
9: 50 Hz HST2
A: 60 Hz, High starting torque 3
A: 60 Hz HST1
B: 60 Hz, High starting torque 4
B: 60 Hz HST2
C: 90 Hz (60 Hz base)
C: 90 Hz
D: 120 Hz (60 Hz base)
D: 120 Hz
E: 180 Hz (60 Hz base)
E: 180 Hz
F: Custom V/f E1-04 through E1-13 settings define the V/f
F: Custom V/F
pattern
These parameters are only applicable when E1-03 is set to F.
To set linear V/f characteristics, set the same values for E1-07
Max Frequency
and E1-09.
In this case, the setting for E1-08 will be disregarded. Ensure
that the four frequencies are set according to these rules:
E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04
Max Voltage
Base Frequency
Mid Frequency A
Mid Voltage A
Min Frequency
Note:
Min Voltage
Mid Frequency B
Mid Voltage B
Base Voltage
Description
Output Voltage (V)
E1-05
E1-12
E1-13
E1-08
E1-10
E1-09
E1-07 E1-06 E1-11 E1-04
Frequency (Hz)
E1-07, E1-08, and E1-10 to E1-13 are not
available in OLV/PM control mode.
YASKAWA ELECTRIC TOEP C710616 45F YASKAWA AC Drive – Z1000 User Manual
Values
Page
Default: 230 V
<1>
134
Min.: 190
<1>
Max.: 240
<2>
Default: F
173
Range: 0 to 9;
A to F
<3> <4>
Default:
134
Min.: 40.0 Hz
Max.: 240.0 Hz
<3> <4>
Default:
Min.: 0.0 V
134
Max.: 255.0 V
<1>
<3> <4>
Default:
134
Min.: 0.0 Hz
Max.: 240.0 Hz
<3>
Default:
134
Min.: 0.0 Hz
Max.: 240.0 Hz
<3>
Default:
Min.: 0.0 V
134
Max.: 255.0 V
<1>
<3> <4>
Default:
134
Min.: 0.0 Hz
Max.: 240.0 Hz
<3>
Default:
Min.: 0.0 V
134
Max.: 255.0 V
<1>
Default: 0.0 Hz
Min.: 0.0
134
Max.: 240.0
Default: 0.0 V
Min.: 0.0
134
<1>
Max.: 255.0
Default: 0.0 V
<5>
134
Min.: 0.0
<1>
Max.: 255.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents