YASKAWA Z1000 User Manual page 373

Hide thumbs Also See for Z1000:
Table of Contents

Advertisement

Terminal
Wire Gauge
Screws
M5
2
14 mm
6 AWG
M8
M5
2
22 mm
4 AWG
M8
2
30 / 38 mm
M8
3 / 2 AWG
2
50 / 60 mm
1 AWG
M8
1/0 AWG
1/0 AWG × 2P
2
70 mm
M8
2/0 AWG
2/0 AWG × 2P
M10
2
M10
80 mm
3/0 AWG × 2P
M12
3/0 AWG × 4P
2
100 mm
M12
4/0 AWG × 2P
4/0 AWG × 4P
150 mm
2
M12
250 kcmil × 2P
300 kcmil × 2P
<1> Codes refer to a set of three crimp terminals and three insulation caps. Prepare input and output wiring using two sets for each connection.
Example 1: Models with 300 kcmil for both input and output require one set for input terminals and one set for output terminals, so the user should
order two sets of [100-051-272].
Example 2: Models with 4/0 AWG × 2P for both input and output require two sets for input terminals and two sets for output terminals, so the user
should order four sets of [100-051-560].
Note:
Use crimp insulated terminals or insulated shrink tubing for wiring connections. Wires should have a continuous maximum allowable
temperature of 75 °C 600 Vac UL-approved vinyl-sheathed insulation.
n
Factory Recommended Branch Circuit Protection
WARNING! Fire Hazard. Install adequate branch circuit protection according to applicable local codes and this manual. Failure to comply
could result in fire and damage to the drive or injury to personnel. The device is suitable for use on a circuit capable of delivering not more
than 100,000 RMS symmetrical amperes, 240 Vac (200 V class) and 480 Vac (400 V class), when protected by branch circuit protection
devices specified in this manual.
Branch circuit protection shall be provided by any of the following: Non-time delay Class J, T, or CC fuses sized at 300% of the drive input
rating, or Time delay Class J, T, or CC fuses sized at 175% of the drive input rating, or MCCB sized at 200% maximum of the drive input
rating.
Yaskawa recommends installing one of the following types of branch circuit protection to maintain compliance with UL508C.
Semiconductor protective type fuses are preferred. Alternate branch circuit protection devices are also listed in
Table D.4 Factory Recommended Z1000 AC Drive Branch Circuit Protection
Nominal Output
Model
Power (HP)
2A0011
3
2A0017
5
2A0024
7.5
2A0031
10
2A0046
15
2A0059
20
2A0075
25
2A0088
30
2A0114
40
YASKAWA ELECTRIC TOEP C710616 45F YASKAWA AC Drive – Z1000 User Manual
Crimp Terminal
Model Number
Machine No.
R14-5
YA-4
R14-8
YA-5
22-5NS
YA-5
R22-8
YA-5
R38-8
YA-5
R60-8
YA-5
CB70-S8
YF-1 YET-300-1
70-8
70-10
YF-1 YET-300-1
80-10
YF-1 YET-300-1
80-L12
YF-1 YET-300-1
100-L12
YF-1 YET-300-1
150-L12
YF-1 YET-300-1
AC Drive Input
MCCB Rating (A)
(A)
<1>
Three-Phase 200 V Class
10.6
16.7
24.2
30.8
46.2
59.4
110
74.8
150
88
175
114
225
Tool
Die Jaw
AD-902
AD-952
AD-953
AD-953
AD-954
AD-955
TD-322,TD-311
TD-322,TD-311
TD-323,TD-312
TD-323,TD-312
TD-324,TD-312
TD-325,TD-313
Time Delay Fuse
<2>
Rating (A)
20
17.5
30
25
40
40
60
50
90
80
100
125
150
175
D.3 UL/cUL Standards
Insulation
Cap
Code
Model No.
TP-014
100-054-034
TP-014
100-054-035
TP-022
100-051-262
TP-022
100-051-263
TP-038
100-051-264
TP-060
100-051-265
100-064-417
TP-080
100-064-250
TP-080
100-064-251
TP-080
100-051-267
TP-080
100-051-558
TP-100
100-051-560
TP-150
100-051-562
Table
Bussmann
Non-time Delay
Semiconductor
Fuse Model
Fuse Rating (A)
<3>
(Fuse Ampere)
<4>
30
FWH-40B (40)
50
FWH-50B (50)
70
FWH-80B (80)
90
FWH-100B (100)
125
FWH-150B (150)
175
FWH-175B (175)
200
FWH-225A (225)
250
FWH-225A (225)
300
FWH-250A (250)
<1>
6.3.