YASKAWA Z1000 User Manual page 63

Hide thumbs Also See for Z1000:
Table of Contents

Advertisement

Wiring sequence should shut off
power to the drive when a fault
output is triggered.
Main
Switch
R
Three-phase
power supply
S
200 V /400 V
50 / 60 Hz
T
12-Pulse/18-Pulse
Rectification
Forward Run / Stop
Reverse Run / Stop
External fault
Fault reset
Multi-function
Multi-speed step 1
digital inputs
(default setting)
Multi-speed step 2
Jog speed
Sink / Source mode
selection wire link
(default: Sink)
2 k
Multi-function
analog inputs
APOGEE FLN Comm.
RS-422/RS-485
48 kbps
BACnet Comm.
RS-485
max. 76.8 kbps
MEMOBUS/Modbus
comm. RS-422/RS-485
max. 115.2 kbps
Metasys N2 Comm.
RS-422/RS-485
96 kbps
<1> Self-cooling motors do not require the same wiring necessary for motors with cooling fans.
YASKAWA ELECTRIC TOEP C710616 45F YASKAWA AC Drive – Z1000 User Manual
Fuse
Main Circuit
R/L 1
S/L 2
ON
SW1
3
T/L
+M
OFF
-M
Control Circuit
S 1
S 2
S 3
S 4
S 5
S 6
S 7
SN
SC
SP
<4>
+
<5>
24 V
+P
FE
Shield ground terminal
<6>
+
V
Power supply +10.5 Vdc, max. 20 mA
Analog Input 1
A 1
(Frequency Reference Bias)
0 to +10 Vdc (20 kW)
4 to 20 mA / 0 to 20 mA (250
A 2
Analog Input 2
(Frequency Reference Bias)
0 to +10 Vdc (20 kW)
4 to 20 mA / 0 to 20 mA (250
AC
0 V
Termination resistor
(120 , 1/2 W)
DIP
Switch S2
+
+
R
R
-
-
+
+
S
S -
IG
Option card
connector
shielded line
twisted-pair shielded line
Figure 3.1 Drive Standard Connection Diagram (example: 2A0011)
U/T 1
V/T 2
ON
SW2
W/T
<2>
OFF
<3>
3 k
(8 mA)
each input
Drive
Jumper S1
A1/A2 Volt./Curr.
Selection
V
<7>
)
I
A1
A2
<7>
)
<8>
Jumper S5
AM/FM Volt./Curr.
Selection
V
I
0 V
FM
AM
CN5
<10>
FE
control circuit terminal
3.2 Standard Connection Diagram
<1>
FU
r1
FV
s1
M
FW
t1
Cooling fan
U
V
M
W
3
Ground
MA
Fault relay output
250 Vac, max. 2 A
MB
30 Vdc, max 2 A
MC
(min. 5 Vdc, 10 mA)
M 1
Multi-function relay output (During Run)
250 Vac, max. 2 A
M 2
30 Vdc, max 2 A
(min. 5 Vdc, 10 mA)
M 3
Multi-function relay output (Zero Speed)
250 Vac, max. 2 A
M 4
30 Vdc, max 2 A
(min. 5 Vdc, 10 mA)
M 5
Multi-function relay output (Speed Agree 1)
250 Vac, max. 2 A
M 6
30 Vdc, max 2 A
(min. 5 Vdc, 10 mA)
FM
Multi-function analog output 1
+
+
(Output frequency)
FM
0 to +10 Vdc (2 mA)
4 to 20 mA
<9>
AM
Multi-function analog output 2
+
+
(Output current)
AC
AM
0 to +10 Vdc (2 mA)
4 to 20 mA
<9>
main circuit terminal
3
63

Hide quick links:

Advertisement

Table of Contents
loading