2.2 Mechanical Installation
Internal/Flush-Mount
An internal/flush-mount requires an installation support set that must be purchased separately. Contact Yaskawa to order an
installation support set and mounting hardware.
1.
Cut an opening in the enclosure panel for the HOA keypad as shown in
2.
Mount the HOA keypad to the installation support.
3.
Mount the installation support set and HOA keypad to the enclosure panel.
M4 × 10
Phillips truss head screw × 4
(for panel widths between 1 (0.04) and 1.6 (0.06))
Note:
Use a gasket between the enclosure panel and the HOA keypad in environments with a significant amount of dust or other airborne debris.
48
Figure 2.8 Panel Cut-Out Dimensions (External/Face-Mount Installation)
HOA Keypad
Figure 2.9 External/Face-Mount Installation
Figure 2.10
Figure 2.10 Internal/Flush Mount Installation
22 (0.87)
22 (0.87)
Unit: mm (in)
14 (0.56)
M3 x 6
Phillips recessed
pan head machine screw x 2
Enclosure panel
illustrates how to attach the Installation Support Set A.
Enclosure panel
YASKAWA ELECTRIC TOEP C710616 45F YASKAWA AC Drive – Z1000 User Manual
Figure
2.11.
HOA Keypad
Installation Support Set A
M3 × 6
Phillips recessed
pan head machine screw × 2
Unit: mm (in)