YASKAWA Z1000 User Manual page 149

Hide thumbs Also See for Z1000:
Table of Contents

Advertisement

n
T2-03: PM Motor Type
Selects the type of PM motor the drive will operate.
No.
T2-03
Setting 0: IPM motor
Setting 1: SPM motor
n
T2-04: PM Motor Rated Power
Specifies the motor rated power in kilowatts.
No.
T2-04
n
T2-05: PM Motor Rated Voltage
Sets the motor rated voltage.
No.
T2-05
<1> Value shown is specific to 200 V class drives. Double value for 400 V class drives.
n
T2-06: PM Motor Rated Current
Enter the motor rated current in amps.
No.
T2-06
n
T2-07: PM Motor Base Frequency
Enter the motor base frequency in Hz.
Note:
T2-07 will be displayed when in OLV/PM.
No.
T2-07
n
T2-08: Number of PM Motor Poles
Enter the number of motor poles.
No.
T2-08
n
T2-10: PM Motor Stator Resistance
Enter the motor stator resistance per motor phase.
No.
T2-10
n
T2-11: PM Motor d-Axis Inductance
Enter the d-Axis inductance per motor phase.
No.
T2-11
YASKAWA ELECTRIC TOEP C710616 45F YASKAWA AC Drive – Z1000 User Manual
Name
PM Motor Type
Name
PM Motor Rated Power
Name
PM Motor Rated Voltage
Name
PM Motor Rated Current
Name
PM Motor Base Frequency
Name
Number of PM Motor Poles
Name
PM Motor Stator Resistance
Name
PM Motor d-Axis Inductance
4.8 Auto-Tuning
Setting Range
0, 1
Setting Range
Determined by o2-04
0.00 to 650.00 kW
Setting Range
<1>
0.0 to 255.0 V
Setting Range
0.0% to 300.0% of the
Determined by o2-04
drive rated current.
Setting Range
0.0 to 240.0 Hz
Setting Range
2 to 48
Setting Range
0.000 to 65.000 Ω
Determined by T2-02
Setting Range
0.00 to 600.00 mH
Determined by T2-02
Default
1
Default
and C6-01
Default
<1>
200.0 V
Default
Default
87.5 Hz
Default
6
4
Default
Default
149

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents