YASKAWA Z1000 User Manual page 90

Hide thumbs Also See for Z1000:
Table of Contents

Advertisement

3.8 Main Circuit Wiring
A – SW1 (ON)
B – Screw (OFF)
If the SW1/SW2 screws are missing, install proper size screws with the proper tightening torque as shown in
NOTICE: Do not use screws of different sizes in SW1 and SW2. Failure to comply may cause overheating.
2A0011
2A0017
2A0024
2A0031
2A0046
2A0059
2A0075
2A0088
2A0114
2A0143
2A0169
2A0211
2A0273
n
Wiring the Main Circuit Terminal
WARNING! Electrical Shock Hazard. Shut off the power supply to the drive before wiring the main circuit terminals. Failure to comply may
result in death or serious injury.
Wire the main circuit terminals after the terminal board has been properly grounded.
Models 2A0011 to 2A0273 and 4A0005 to 4A0302 have a cover placed over the 12/18 rectification terminals prior to shipment
to help prevent miswiring. Use wire cutters to cut away covers as needed for terminals.
Refer to
Figure 3.4
on page
n
Main Circuit Connection Diagram
Refer to Main Circuit Connection Diagram on page 65
90
A
B
Figure 3.37 EMC Filter Switch Location (4A0302)
Table 3.6 SW1/SW2 Screw Sizes and Tightening Torques
Drive Model
4A0005
4A0008
4A0011
4A0014
4A0021
4A0027
4A0034
4A0040
4A0052ooB
4A0052ooA
4A0065
4A0077
4A0096
4A0124
4A0156
4A0180
4A0240
4A0302
65
for details.
C
B
C – SW2 (ON)
SW1/SW2 Screw Size
M3 × 16
M3 × 16
M3 × 16
M5 × 30
M5 × 25
M5 × 25
M5 × 25
when wiring terminals on the main power circuit of the drive.
YASKAWA ELECTRIC TOEP C710616 45F YASKAWA AC Drive – Z1000 User Manual
Table
3.6.
Tightening Torque
0.5 to 0.6 N•m
0.5 to 0.6 N•m
0.5 to 0.6 N•m
2 to 2.5 N•m
2 to 2.5 N•m
2 to 2.5 N•m
2 to 2.5 N•m

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents