3. Engine SP Mode Tables
1-950-003 Dev Cooling Fan
1-950-005 Ozone Fan
1-950-006 Fusing Fan
1-950-007 Paper Exit Cooling Fan
1-950-011 PSU Cooling Fan
1-950-051 Dev Suction Fan: Right
1951
[Fan Start Time Set]
1-951-003 Dev Cooling Fan
1-951-005 Ozone Fan
1-951-006 Fusing Fan
1-951-007 Paper Exit Cooling Fan
1-951-011 PSU Cooling Fan
1-951-051 Dev Suction Fan: Right
1952
[Fan Control Off Mode Time Set]
1-952-001 -
1953
[Extra Fan Control]
1-953-001 Extra Fan Cooling State
1-953-002 Execution Temp. Threshold
1-953-003 Cancellation Temp. Threshold
218
*ENG
[0 to 120 / 0 / 1min/step]
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
[0 to 900 / 120 / 1sec/step]
*ENG
[0 to 900 / 0 / 1sec/step]
*ENG
[0 to 900 / 120 / 1sec/step]
*ENG
[0 to 900 / 120 / 1sec/step]
*ENG
[0 to 900 / 120 / 1sec/step]
*ENG
[0 to 900 / 0 / 1sec/step]
*ENG
[0 to 60 / 10 / 1min/step]
*ENG
[0 or 1 / 0 / 1/step]
0: Disable
1: Enable
*ENG
[0 to 100 / * / 0.1deg/step]
*MP C3004/C3504: 41
*MP C4504/C5504/C6004: 39
*ENG
[0 to 100 / 2 / 0.1deg/step]