• Date of unit installation
• Unit total counter at installation (no. of sheets, travel distance)
• Date of unit operation
• Unit total counter during operation (no. of sheets, travel distance)
• Unit parts information
• Total counter
• Total color counter

Pressure release filter

To prevent scattering of toner, the air pressure in the development unit is released via a filter.
Development drive
The following table shows the drive components for each model.
A gear for developer coil rotation is provided on the front side of the unit (downstream side).
MP C3004/C3504:
Drive source for Bk
PCU: Black / Image Transfer Motor
The PCU: Black / Image Transfer Motor is also used for the image transfer unit and waste toner bottle.
Drive is switched by the development solenoid.
MP C4504/C5504/C6004:
Drive source for Bk
Development Motor: Black
Development Bias
Applied from the development power pack via a plate spring on the front cover of the PCDU.

Removal of PCDU Seals

Seals for all colors of MP C4504/C5504/C6004, and for Bk of MP C3004/C3504 will be wound
up with the winding lever [B].
Remove the seal by winding it with the shaft [A] on the vent filter side.
PCDU (Photo Conductor and Development Unit)
Drive source for C, M, Y
Development Motor: CMY
Drive source for C, M, Y
Development Motor: CMY