No.
Type
Authentication error
The authentication for the RCG-M fails at a dial up connection.
• Incorrect SP settings
-001
-
• Disconnected telephone line
• Disconnected modem board
Disconnected Local Area Network card
Check and set the correct user name (SP5816-156) and password (SP5816-157).
Incorrect modem setting
Dial up fails due to the incorrect modem setting.
-004
-
Same as -001
Check and set the correct AT command (SP5819-160).
Communication line error
The supplied voltage is not sufficient due to the defective communication line or
defective connection.
-005
-
Same as -001
Consult with the user's local telephone company.
No.
Type
Incorrect dial up connection
-001: Program parameter error
-002: Program execution error
CTL
651
An unexpected error occurs when the modem (RCG-M) tries to call the center with
C
a dial up connection.
• Caused by a software bug
No action required because this SC does not interfere with operation of the machine.
Details (Symptom, Possible Cause, Troubleshooting Procedures)