005 Execution Flag: Bk
006 Execution Flag: C
007 Execution Flag: M
008 Execution Flag: Y
3041
[Process Control Type]
Bias Control
001
Enables or disables the process control.
LD Power Control
002
Selects the LD power control mode.
AutoControl Prohibition
Set
003
Enables or disables the automatic process control at power-on or door opening.
Pre-ACC Process Control
004
Selects the process control mode that is done before ACC.
005 P-Pattern Selection
*ENG
[0 or 1 / 0 / 1/step]
*ENG
0: Flag OFF, 1: Flag ON
This flag is cleared after executing TD sensor
*ENG
initialization.
*ENG
[0 or 1 / 1 / 1/step ] Alphanumeric
0: FIXED (Use the fixed values for the charge DC bias
*ENG
and development DC bias set with SP2-005 and
SP2-229.)
1: CONTROL
[0 or 1 / 1 / 1/step] Alphanumeric
*ENG
0: FIXED (at the value in SP2221-xxx)
1: CONTROL (adjusted by process control)
[0 or 1 / 0 / 1/step] Alphanumeric
*ENG
0: Permit
1: Forbid
[0 to 2 / 2 / 1/step]
0: Not Execute
*ENG
1: Process Control
2: TC Control
[0 to 2 / 2 / 1/step]
0: FIXED
*ENG
1: INITIALIZED
2: CALCULATED
Main SP Tables-3