5. System Maintenance
074 Rotation %: ITB Cleaning Unit
075 Rotation %: Fusing Unit
076 Rotation %: Fusing Pad
077 Rotation %: Fusing Belt
078 Rotation %: PTR Unit
079 Rotation %:ITB T-Collect Bottle
080 Rotation %:PCU T-Collect Bottle
Displays the value given by the following formula:
-091 to
(Current count ÷ Yield count) x 100, where "Current count" is the current values in the counter
-108
for the part, and "Yield count" is the recommended yield.
5
[0 to 255 / 0 / 1 %/step ]
091 Page (%): PCU: Bk
092 Page (%): PCU: C
093 Page (%): PCU: M
094 Page (%): PCU: Y
095 Page (%): Development Unit: Bk
096 Page (%): Development Unit: C
097 Page (%): Development Unit: M
098 Page (%): Development Unit: Y
099 Page (%): Developer: Bk
100 Page (%): Developer: C
101 Page (%): Developer: M
102 Page (%): Developer: Y
103 Page (%): ITB Unit
104 Page (%): ITB Cleaning Unit
105 Page (%): Fusing Unit
488