3. Appendix: SP Mode Tables
Execute
Executes the nip band measurement between heating roller and pressure roller.
001
If the nip band width is not 8 mm, and fusing is not good, replace the pressure roller or install
a new fusing unit.
Pre-Idling Time
002
Specifies the fusing rotation time before executing SP1152-001.
3
Stop Time
003
Specifies the time for paper staying at the nip.
Feed Time
004
Specifies the feeding time from the tray to the fusing unit at the fusing nip band check.
[Low Temp. Start Up]
DFU
1153
The following SPs below are desgined for the factory use only. Do not change the adjusted
setting.
Temp.:Threshold Value1
001
Sepcifies the threshold temperature 1 for the warming up in the low temperature condition.
Temp.:Threshold Value2
002
Sepcifies the threshold temperature 2 for the warming up in the low temperature condition.
Temp.:Target
003
Sepcifies the target temperature for the warming up in the low temperature condition.
Temp.: Rotation Threshold
Value1
005
Sepcifies the threshold temperature 1 for the warming up rotation in the low temperature
condition.
Time:Heat Storage Devision1 * ENG
010
Sepcifies the execution time 1 for the warming up in the low temperature condition.
64
-
-
*ENG
[0 to 999 / 600 / 1 sec/step]
* ENG
[0 to 100 / 20 / 1 sec/step]
* ENG
[0 to 10000 / 5000 / 1 msec./step]
* ENG
[-10 to 100 / 5 / 1°C./step]
* ENG
[-10 to 100 / 17 / 1°C./step]
* ENG
[0 to 100 / 100 / 1°C./step]
* ENG
[-10 to 100 / 30 / 1°C./step]
[0 to 250 / 60 / 1 sec./step]