Ricoh D104 Field Service Manual page 394

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

5. System Maintenance
[Dev. DC Control:Display]
Normal: 120 mm/sec, Low: 70 mm/sec
3621
Displays the development DC bias adjusted with the process control for each line speed and
color.
001 Normal Speed:Bk
002 Normal Speed:C
003 Normal Speed:M
004 Normal Speed:Y
009 Low Speed:Bk
010 Low Speed:C
5
011 Low Speed:M
012 Low Speed:Y
[Charge DC Control: Display]
Normal: 120 mm/sec, Low: 60 mm/sec
3631
Displays the charge DC voltage adjusted with the process control for each line speed and
color.
001 Normal Speed:Bk
002 Normal Speed:C
003 Normal Speed:M
004 Normal Speed:Y
009 Low Speed:Bk
010 Low Speed:C
011 Low Speed:M
012 Low Speed:Y
392
*ENG
*ENG
*ENG
*ENG
[0 to 700 / 550 / 1 -V/step]
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
[0 to 2000 / 690 / 1 -V/step]
*ENG
*ENG
*ENG
*ENG

Advertisement

Table of Contents
loading

This manual is also suitable for:

D106

Table of Contents