3. Appendix: SP Mode Tables
Heater OFF Time: Normal
002
Speed: BW
Heater OFF Time:Low
005
Speed:FC
Heater OFF Time:Low
006
Speed:BW
Heater OFF Time: After State
3
007
Shift
[Fusing SC Issue Time Info]
DFU
1141
The following SPs below are desgined for the factory use only. Do not change the adjusted
setting.
001 SC Number
SC Cause
002
Shows the SC cause
0: Timeout 1, 1: Timeout 2, 2: Timeout 3, 4 to 9: Not used
Htg Roller:Ctr Diff1
101
Displays the calculated temperature at the center of the heating roller when an SC was issued.
Htg Roller:End Diff1
104
Displays the calculated temperature at the end of the heating roller when an SC was issued.
Htg Roller:End Det1
105
Displays the detected temperature at the end of the heating roller when an SC was issued.
Htg Roller:End Corr1
106
Displays the ambient temperature at the end of the heating roller when an SC was issued.
Press Roller Temp Value1
107
Displays the temperature at the pressure roller when an SC was issued.
Press Roller:End Temp Value1
108
Displays the temperature at the end of the pressure roller when an SC was issued.
62
*ENG
[0 to 20000 / 1200 / 1 msec./step]
*ENG
[0 to 20000 / 6300 / 1 msec./step]
*ENG
[0 to 20000 / 1400 / 1 msec./step]
*ENG
[0 to 20000 / 17000 / 1 msec./step]
*ENG
Displays the issued SC number.
*ENG
[0 to 9 / - / 1/step]
*ENG
[-20 to 260 / - / 1 deg/step]
*ENG
[-100 to 260 / - / 1 deg/step]
*ENG
[-10 to 260 / - / 1 deg/step]
*ENG
[-10 to 260 / - / 1 deg/step]
*ENG
[-10 to 260 / - / 1 deg/step]
*ENG
[-10 to 260 / - / 1 deg/step]