Ricoh D104 Field Service Manual page 344

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

5. System Maintenance
003 Execute:Mode c
2112
[TM/P Sensor Test] ID Sensor Check FA
001 Execute
[Skew Adjustment]
Specifies a skew adjustment value for the skew motor M, C or Y.
2117
5
These SPs must be used when a new laser optics housing unit is installed, see "Laser Optics
Housing Unit" in the "Replacement and Adjustment" section.
001 Pulse: C
002 Pulse: M
003 Pulse: Y
2118
[Skew Adjustment]
001 Execute: C
002 Execute: M
003 Execute: Y
[Skew Adjustment Display]
2119
Displays the current skew adjustment value for each skew motor.
001 C
002 M
003 Y
342
Executes the rough line position adjustment once.
After doing this SP, make sure to execute
-
SP2111-001 or -002. Otherwise, the line position
adjustment is not perfectly done.
This SP is used to check the ID sensors at the factory.
The results of this SP are displayed in SP2140 to
SP2145.
*ENG
*ENG
[–75 to 75 / 0 / 1 pulse/step]
*ENG
*ENG
Changes the current skew adjustment values to the
values specified with SP2117.
*ENG
These SPs must be used when a new laser optics
housing unit is installed. For details, see "Laser
Optics Housing Unit" in the "Replacement and
*ENG
Adjustment" section.
*ENG
*ENG
[–75 to 75 / 0 / 1 pulse/step]
*ENG

Advertisement

Table of Contents
loading

This manual is also suitable for:

D106

Table of Contents