System SP2xxx
SP2-XXX (Drum)
[Charge DC V:Fixed] DFU
2005
(Paper Type, Process Speed, Color)
Paper Type –> Plain, Thick 1, Thick 2
Adjusts the DC component of the charge roller bias in the various print modes.
Charge bias (DC component) is automatically adjusted during process control; therefore,
adjusting these settings does not effect while process control mode (SP3-041-1 Default: ON)
is activated. When deactivating process control mode with SP3-041-1, the values in these
SP modes are used for printing.
001 Plain: Bk
002 Plain: C
003 Plain: M
004 Plain: Y
009 Thick 2&FINE: Bk
010 Thick 2&FINE: C
011 Thick 2&FINE: M
012 Thick 2&FINE: Y
[Charge DC V:Fixed] DFU
(Paper Type, Process Speed, Color)
Paper Type –> Plain, Thick 1, Thick 2
2006
Adjusts the AC component of the charge roller bias in the various print modes.
Charge bias (AC component) is adjusted by environment correction (SP2-007-xxx to
SP2-011-xxx). These SPs are activated only when SP2-012-1 is set to "1: manual control".
*ENG
*ENG
*ENG
*ENG
[0 to 1000 / 600 / 10 –V/step]
*ENG
*ENG
*ENG
*ENG
System SP2xxx
3
71