System Sp3Xxx; Sp3-Xxx (Process) - Ricoh D104 Field Service Manual

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

System SP3xxx

SP3-XXX (Process)

3011
[Process Cont. Manual Execution]
001 Normal Procon
002 Toner Density Adjst
003 Procon BF-ACC
004 With Full MUSIC
005 With Normal MUSIC
[Process Cont. Check Result] Process Control Self-check Result
Displays the result of the latest process control self-check.
All colors are displayed. The results are displayed in the order "Y C M K"
3012
e.g., 11 (Y) 99 (C) 11 (M) 11 (K): The self-check for Cyan failed but the others were
successful.
See the "Error Condition Tables" in the Process Control Error section for details.
Executes the normal process control manually
(potential control).
-
Check the result with SP3-325-001 after executing
this SP.
Executes the toner density adjustment manually.
-
Check the result with SP3-325-001 after executing
this SP.
Executes the process control that is normally done
before ACC.
-
The type of process control is selected with
SP3-041-004.
Executes the process control that is normally done
-
at the same time as MUSIC. This SP does the MUSIC
(line position adjustment) twice.
Executes the process control that is normally done
-
at the same time as MUSIC. This SP does the MUSIC
(line position adjustment) once.
System SP3xxx
3
157

Advertisement

Table of Contents
loading

This manual is also suitable for:

D106

Table of Contents