5. System Maintenance
001 Mitigation On/Off
002 Mitigation Time
5415
[Password Attack]
5
001 Permissible Number
002 Detect Time
5416
[Access Information]
001 Access User Max Num
002 Access Password Max Num
003 Monitor Interval
5417
[Access Attack]
422
Switches on/off masking of continuously used
IDs and passwords that are identical.
[0 to 1 / 0 /1]
*CTL
0: Off
1: On
Sets the length of time for excluding continuous
access for identical user IDs and passwords.
*CTL
[0 to 60 / 15 / 1 min.]
Sets the number of attempts to attack the system
with random passwords to gain illegal access to
*CTL
the system.
[0 to 100 / 30 / 1 attempt]
Sets the time limit to stop a password attack once
such an attack has been detected.
*CTL
[1 to 10 / 5 / 1 sec.]
Limits the number of users used by the access
exclusion and password attack detection
*CTL
functions.
[50 to 200 / 200 / 1 users]
Limits the number of passwords used by the
access exclusion and password attack detection
*CTL
functions.
[50 to 200 / 200 / 1 passwords]
Sets the processing time interval for referencing
user ID and password information.
*CTL
[1 to 10 / 3 / 1 sec.]