Ricoh D104 Field Service Manual page 767

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

003 Pressure Center
005 Thermister Atmosphere
006 Pressure End
The pressure roller has no lamp.
1107
[Standby Target Temp. Setting]
Stanby/Preheat1: Center
001
Specifies the temperature of the heating roller for the ready or energy save 1 mode.
-002
DFU
to -006
These SPs are desgined for the factory use only. Do not change the adjusted setting.
Stanby/Preheat1: Press
002
Specifies the temperature of the pressure roller for the ready or energy save 1 mode.
Preheat2: Center
003
Specifies the temperature of the heating roller for the energy save 2 mode.
Preheat2:Press
004
Specifies the temperature of the pressure roller for the energy save 2 mode.
Low Power:Center
005
Specifies the temperature of the heating roller for the low power mode.
Low Power:Press
006
Specifies the temperature of the pressure roller for the low power mode.
Print Ready:Center
007
Specifies the temperature of the heating roller for the print ready condition.
Print Ready:Press (DFU)
Specifies the temperature of the pressure roller for the print ready condition.
008
DFU
This SP is desgined for the factory use only. Do not change the adjusted setting.
-
[–10 to 250 / 0 / 1 deg/step]
-
[–10 to 250 / 0 / 1 deg/step]
-
[–10 to 250 / 0 / 1 deg/step]
*ENG
[100 to 150 / 135 / 1 deg/step]
*ENG
[0 to 200 / 0 / 1 deg/step]
*ENG
[0 to 200 / 130 / 1 deg/step]
*ENG
[0 to 200 / 0 / 1 deg/step]
*ENG
[0 to 200 / 0 / 1 deg/step]
*ENG
[0 to 200 / 0 / 1 deg/step]
*ENG
[120 to 150 / 130 / 1 deg/step]
*ENG
[0 to 200 / 10 / 1 deg/step]
System SP1-xxx