High Coverage Threshold:2
006
Specifies the threshold for the high coverage image to the drum lubrication mode handled
by the setting 2 (SP2-016-003).
High Coverage Threshold:3
007
Specifies the threshold for the low coverage image to the drum lubrication mode handled
by the setting 3 (SP2-016-004).
Application Time:1
008
Specifies the execution time for the drum lubrication mode of the setting 1 (SP2-016-002).
Application Time:2
009
Specifies the execution time for the drum lubrication mode of the setting 2 (SP2-016-003).
Application Time:3
010
Specifies the execution time for the drum lubrication mode of the setting 3 (SP2-016-004).
Average Coverage:1:K
011
Displays the average coverage of black color for the setting 1.
Average Coverage:1:M
012
Displays the average coverage of magenta color for the setting 1.
Average Coverage:1:C
013
Displays the average coverage of cyan color for the setting 1.
Average Coverage:1:Y
014
Displays the average coverage of yellow color for the setting 1.
015 Average Coverage:2:K
016 Average Coverage:2:M
017 Average Coverage:2:C
018 Average Coverage:2:Y
019 Average Coverage:3:K
020 Average Coverage:3:M
*ENG
[0 to 100 / 20 / 0.01%/step]
*ENG
[0 to 100 / 0.5 / 0.01%/step]
*ENG
[0 to 99 / 0 / 1 sec./step]
*ENG
[0 to 99 / 0 / 1 sec./step]
*ENG
[0 to 99 / 0 / 1 sec./step]
*ENG
[0 to 100 / 0.05 / 0.01%/step]
*ENG
[0 to 100 / 0.05 / 0.01%/step]
*ENG
[0 to 100 / 0.05 / 0.01%/step]
*ENG
[0 to 100 / 0.05 / 0.01%/step]
*ENG
[0 to 100 / 0.05 / 0.01%/step]
*ENG
[0 to 100 / 0.05 / 0.01%/step]
*ENG
[0 to 100 / 0.05 / 0.01%/step]
*ENG
[0 to 100 / 0.05 / 0.01%/step]
*ENG
[0 to 100 / 0.05 / 0.01%/step]
*ENG
[0 to 100 / 0.05 / 0.01%/step]