Ricoh D104 Field Service Manual page 776

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

3. Appendix: SP Mode Tables
002 Rotation Time
[CPM Down Setting] DFU
Specifies the settings for the CPM down mode.
1124
DFU
The following SPs below are desgined for the factory use only. Do not change the adjusted
setting.
3
001 Low:Down Temp.
Specifies the CPM down threshold temperature for the low temperature condition. If the fusing
temperature decreases -20°C (adjustable) below the target temperature, the machine enters
the CPM down mode.
002 Low:Up Temp.
Specifies the CPM up threshold temperature for the low temperature condition. If the fusing
temperature increases -15°C (adjustable) below the target temperature, the machine enters
the CPM up mode.
003 Low :1st CPM
Specifies the 1st CPM down ration against the normal CPM in the low temperature condition.
004 Low :2nd CPM
Specifies the 2nd CPM down ration against the normal CPM in the low temperature condition.
005 Low :3rd CPM
Specifies the 3rd CPM down ration against the normal CPM in the low temperature condition.
006 High :1st CPM
Specifies the 1st CPM down ration against the normal CPM in the high temperature condition.
007 High:2nd CPM
Specifies the 3rd CPM down ration against the normal CPM in the high temperature condition.
008 High:3rd CPM
Specifies the 1st CPM down ration against the normal CPM in the high temperature condition.
High:1st CPM Down
009
Temp.:A3
58
*ENG
[0 to 10000 / 600 / 1 msec/step]
*ENG
[-50 to 0 / -20 / 1 deg/step]
*ENG
[-50 to 0 / -15 / 1 deg/step]
*ENG
[10 to 100 / 80 / 5 %/step]
*ENG
[10 to 100 / 65 / 5 %/step]
*ENG
[10 to 100 / 50 / 5 %/step]
*ENG
[10 to 100 / 75 / 5 %/step]
*ENG
[10 to 100 / 50 / 5 %/step]
*ENG
[10 to 100 / 25 / 5 %/step]
*ENG
[100 to 225 / 200 / 1 deg/step]