SP No.
SP1-801-020
SP1-801-022
SP1-801-024
SP1-801-026
SP1-801-028
2. An error ("1") occurs in SP1-803-005.
[Setting values of the following SPs + input value with SP1-803-001] > motor speed adjustable range
e.g.) 1.5 (SP1-801-025) + 1 (SP1-803-001 to -003) = 2.5
In this case, "2.5" is over the maximum adjustable value ("2") of the SP1-801-025. As a result, the
result of the motor speed adjustment issues "1" (error).
• Adjust the settings of SP1-830-001 to -003 so that the total value (motor speed setting value +
input value) is within the adjustable range for each motor described below.
SP No.
SP1-801-025
SP1-801-027
SP1-801-033
SP1-801-034
SP1-801-035
SP1-801-036
SP1-801-037
SP1-801-038
SP1-801-039
SP1-801-040
SP1-801-041
SP1-801-042
SP1-801-043
Max.
Min.
2
-2
By-pass:120 (0.3 default)
2
-2
Inverter:CW120 (0 default)
2
-2
Inverter:CCW120 (0 default)
2
-2
Duplex Entrance:120 (0.3 default)
2
-2
Duplex Exit:120 (0.3 default)
Max.
Min.
2
-2
Duplex Entrance:60
2
-2
Duplex Exit:60
4
-4
Regist Mot:60:1200dpi
2
-2
Feed1:CW60:1200dpi
2
-2
Feed1:CCW60:1200dpi
2
-2
Feed2:CW60:1200dpi
2
-2
Feed2:CCW60:1200dpi
2
-2
By-pass:60:1200dpi
2
-2
Inverter:CW60:1200dpi
2
-2
Inverter:CCW60:1200dpi
6
-6
FusingMot:60:1200dpi
4
-4
BkOpcDevMot:60:1200dpi
4
-4
TransferMot:60:1200dpi