Glareshield lighting is accomplished using a fluorescent light
recessed
into the
glareshield.
This light is controlled by rotating the
~.
GLARESHIELD
L
T dimmer, located
below
the nav indicators.
Rotating
the
dimmer clockwise
increases
light intensity, and
rotating
the
dimmer counterclockwise
decreases light
intensity.
Pedestal lighting
consists
of
a single,
hooded light located
above
the fuel
selector.This light is
controlled
by rotating the PEDESTAL
L T dimmer, located below the nav indicators. Rotating the dimmer
clockwise
increases
light
intensity,
and
rotating the dimmer
counterclockwise
decreases light intensity.
Panel lighting is
accomplished using
individual
lights mounted in
each
instrument
and gauge.
These
lights are wired
in parallel and
are
controlled by the PANEL L T
dimmer,
located below the nav
indicators.
Rotating
the dimmer clockwise increases light intensity,
and rotating the
dimmer counterclockwise decreases light
intensity.
Back
lighting
intensity for
the
radios
and
instrument lighting for
the
RH
nav indicators,
in the pilot's panel, is
controlled by
the
TST
(TEST)
-
BRT (DAY)
-
DIM (NIGHT) switch. When the
switch is in
the BRT (DAY) position, this
lighting
may be off
regardle
ss
of
the
RADIO
LT
dimmer position.
Some
earlier aircraft will
always have
this
lighting
controlled by the RADIO L T
dimmer.
Pilot control
wheel
lighting is
accomplished by use of a
rheostat
and
light
assembly,
located underneath the
pilot
control
wheel yoke
.
The
light provides downward
illumination
from the bottom
of
the
yoke
to
the
pilot's
lap area.
To
operate
the light, first turn
on
the
NAV
light switch, then adjust
the map
light intensity with
the
knurled
rheostat
knob.
Rotating
the
dimmer
clockwise
increases light
intenSity, and rotating
the
dimmer counterclockwise
decreases light
intensity.
Regardless
of
the light system in question, the
most
probable
cause
of
a light
failure is a burned
out
bulb. However, in the event
any of the lighting systems fail to illuminate
when
turned on, check
the appropriate circuit breaker.
If
the ci
rcuit
breaker has
opened,
and
there is no
obvious
indication
of a short circuit
(smoke
or
odor),
turn
off the light switch
of the affected lights,
reset
the
breaker, and
turn the
switch
on
again.
If the breaker
opens
again.
do
not
reset
it.